10 Isolation resistance measurement (Iso.)
52
ARGUS Copper Box
Settings
Description
Polarity:
Determines whether the polarity of the measurement is inverted. Standard is selected
such that e.g. a correctly connected passive test termination (PPA) is non-conducting. If
the PPA is reversed due to reversed connection, the display shows the value PPA
(~470 kΩ). If this occurs, reverse the polarity.
Default:
Standard
Range limit:
Sets the limiting thresholds for isolation resistance measurement (see also page 14). The
measurement is only carried out up to the set threshold.
The threshold applies for isolation resistance measurement when a measurement voltage
of 105 V is selected.
Default:
1000 M
Ω
Measurement voltage:
Determines whether isolation measurement is to be conducted at a high 105 V or low 8 V
voltage. With 8 V, it is possible e.g. to measure against a connected NTBA, so that this
does not become low-ohm (above approx. 10 V) and falsify the measurement.
Default:
High voltage (105 V)
Susceptibility:
Selects the susceptibility with which ARGUS performs isolation resistance measurement.
Robust for ext.
voltage:
Insecure
(fast):
Default:
The measurement is reliable in the event of external voltages up to
17 V.
Using another measuring method, the measurement is extremely fast but
much more susceptible to interference.
Reliable for external voltages
Display mode:
Determines whether the standard display (Normal display mode) or min./max display
(incl. Min./max. display mode) is used.
Default:
Normal display