![Argus 165 Manual Download Page 281](http://html.mh-extra.com/html/argus/165/165_manual_2969439281.webp)
23 Copper tests
ARGUS 165
281
23.5.4 Examples
The following signal forms can help you in interpreting the reflection responses that
ARGUS displays.
Examples:
Open cable
The reflected pulse is positive. No proxi-
mate interference sources or the far end of
the line can be seen.
Short-circuit
The reflected pulse is negative. No proxi-
mate interference sources or the far end of
the line can be seen.
Mismatch
Different line cross-sections were used.
The greater the mismatch, the greater the
amplitude of the reflection.
Poor contact point
A poor contact between two lines distorts
the reflection into an S-shape. The worse
the contact, the greater the reflection.
Summary of Contents for 165
Page 26: ...4 Quick start guide 26 ARGUS 165 ...
Page 170: ...15 IP tests 170 ARGUS 165 ...
Page 235: ...19 Parallel tests ARGUS 165 235 ...
Page 284: ...23 Copper tests 284 ARGUS 165 ...