40
Media Calibration
After the first time of installation, the printer media is changed or
the media sensor board is replaced, the media sensor calibration
must be performed.
1. Load the media (and ribbon for thermal transfer printing)
properly.
2. Shift the media sensor to proper position.
3. Press and hold
PAUSE/CALIBR.
button then turn on the
power switch.
4.
When “CALIBRATION…” is displayed on the LCD, release
the FEED button.
During media calibration, a few inches of media will be fed out.
The READY and MEDIA indicators will blink for few seconds
during calibration is proceeding. Without the proper
calibration, the gap detection will not stable especially for the
small label (less than 2.0 inches in height).
After the calibration, all the related parameters will be stored in
the EEPROM of main board.
Note:
After the first time of installing the media or the media type is
changed, this procedure must be carried out. Failing to do it, the
media-empty and media-gap detection might be incorrect.
Summary of Contents for G Series
Page 1: ...I Argox website http www argox com G Series Industrial Barcode Printer User s Manual ...
Page 8: ...8 Power Switch AC Power Connector Power Jack AC Electrical Outlet ...
Page 9: ...9 Parts and Features Top Access Door LCD Display Front Access Door ...
Page 11: ...11 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 17: ...17 ...
Page 18: ...18 ...
Page 19: ...19 10 ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 48: ...48 6 Click Finish 7 Select Install printer drivers and Click Next ...
Page 70: ...70 5 Remove the tear off bracket 5 by releasing screws 4 shown in Figure below ...
Page 72: ...72 7 Insert the left side of cutter bracket 7 and secure screws 6 to the TPH module ...