89
Exit
Code-128
ISBT enable:
This feature is commonly used in a blood bank
for identification.
ISBT concatenation timeout:
This feature is to setup the
timeout duration of ISBT concatenation.
Field separator code:
This feature is only used for
UCC/EAN-128 format. This Field separator code means you
can reassign second or after a FNC1 for
your usage. The
default of ASCII code is <GS>(1D
16
).
UCC/ EAN 128 ID setting:
To setting the code ID for
UCC/EAN-128 output format.
Option Bar Code
Option
Alphanumeric
Entry
ISBT enable
Disable
Enable normal
00
*
01
Field separator code
00-ffH ASCII
code
00-ffH
1DH
*
UCC/EAN-128
ID setting
00-ffH ASCII
code
00-ffH
< # >
*
Program