USER and INSTALLATION MANUAL 

 

 

X3MI ECO 52SHB 
X3MI ECO 61SH 
X3MI ECO 71SH 
X3MI ECO 80SH 
X3MI ECO 105SH 
X3MI ECO 120SH 

 

 
 
 
 

 

OUTDOOR UNITS 

Please read this manual carefully before installing and using the air conditioner, and 
retain for future reference. 

V 01/20 

X3 ECO PLUS  

MULTI SPLIT AIR 

CONDITIONERS – R32

 

INDOOR UNITS 

X3I ECO PLUS 27 HL WF 

 

X3I ECO PLUS 35 HL WF 

 

X3I ECO PLUS 52 HL WF 

 

X3I ECO PLUS 70HL WF 

 

Summary of Contents for X3 ECO PLUS

Page 1: ...5SH X3MI ECO 120SH OUTDOOR UNITS Please read this manual carefully before installing and using the air conditioner and retain for future reference V 01 20 X3 ECO PLUS MULTI SPLIT AIR CONDITIONERS R32 INDOOR UNITS X3I ECO PLUS 27 HL WF X3I ECO PLUS 35 HL WF X3I ECO PLUS 52 HL WF X3I ECO PLUS 70HL WF ...

Page 2: ...mp 89 Maintenance 90 Electrical connections 90 Testing and operation Post installation checks 94 Safety operation of flammable refrigerant 94 Functional testing 96 Appendices Piping configuration 96 Procedure for extending the piping 96 INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012 19 EU At the end of its working life this equipment must not be disp...

Page 3: ...perate repair store the unit without following the instruction manual or related regulations 6 After verification the problem or dispute is caused by quality specifications or by the performance of parts or components produced by other manufacturers 7 The damage is caused by natural disasters bad use of the environment or force majeure Warning Do not try to accelerate the defrosting process or to ...

Page 4: ... for their safety Children aged from 3 and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the app...

Page 5: ...the radio equipment operates 2400MHz 2483 5MHz Maximum radio frequency power transmitted in the frequency band s in which the radio equipment operates 20dBm WARNING In case of smoke or burning smell turn off the power supply and contact the service center If the problem persists the unit could be damaged and cause electrical shock or fire It is necessary that power supply adopts the special circui...

Page 6: ... shock For this reason it is advisable to contact a service center for repairs Check if the installed media is sufficiently stable If damaged it can cause the equipment to fall and cause injury Do not climb on the outdoor unit or place anything on it The falling of the outdoor unit can be dangerous Earthing The unit must be properly grounded The cable grounding must be connected with the appropria...

Page 7: ...ir inlet pannellino panel filtro filter Tasto ausiliario auxiliary button Deflettore orizzontale horizontal flap uscitadell aria air outlet Spia alimentazione power indicator Finestrella ricevitore receiver window Spia temperatura temperature indicator telecomando remote control Spia riscaldamento Heating indicator Spia raffreddamento Cooling indicator ...

Page 8: ...V 01 20 56 Outdoor unit Unitàesterna Outdoor unit ingresso aria air inlet impugnatura handle uscita aria air outlet GUIDE TO THE REMOTE CONTROL AND DISPLAY Remote control buttons ...

Page 9: ...Auto mode with the standard remote control and then you can connect it to the app and set the temperature in Auto mode via smart phone or wired control If the remote control is combined with a unit that can t control the temperature in Auto mode the temperature set in this mode may not be valid or the temperature shown on the unit display may not match that shown on the remote control s display in...

Page 10: ...utton to adjust the fan speed Pressing the SWING button will allow you to adjust the angle of airflow N B To prevent blasts of cold air from being blown into the room there will be a delay of 1 5 minutes after selecting heat mode before operation begins The actual delay will depend on the indoor ambient temperature The temperature can be set between 16 30 C and four fan speeds are available automa...

Page 11: ...p will be maintained In the SWING mode when switching from off to this mode if you press the button again after 2 sec has elapsed the unit will go directly off if instead the key is pressed a second time before 2 sec has passed the change in the position of the flap will follow the sequence illustrated above 7 SWING vertical button Press this button to set the swing angle up down You can cycle thr...

Page 12: ...nstant temperature 3 When the initial temperature is set to 28 C 30 C after activating the Sleep function the temperature will decrease by 1 C every hour after three hours the temperature will decrease and the unit will maintain this constant temperature SLEEP 3 it is possible to customize the sleep curve in this mode keep the TURBO key pressed for a long time to access the setting of the CUSTOM S...

Page 13: ...will re appear on the display CANCELLING TIMER OFF If the TIMER OFF function is enabled press the TIMER OFF button to cancel the setting N B You can set the TIMER ON and TIMER OFF function in OFF and ON mode Before you set the TIMER ON or TIMER OFF function set the clock When the TIMER ON or TIMER OFF function is enabled the air conditioner will turn on or off according to the set time Turning the...

Page 14: ... start the air purification function the symbol appears on the display Press the button a second time to start the purification and sanitizing function at the same time symbols and appear Press the button for the third time to turn off both functions Press the button the fourth time to start the sanitizing function appears Press this button again to repeat the operations listed above 16 TEMP butto...

Page 15: ... CLOCK again simultaneously to exit the 8 C heating function N B When the 8 C heating function is enabled the fan will operate at the default automatic speed and cannot be adjusted The remote control will not send a signal to the unit when the TURBO button is pressed The SLEEP and 8 C heating functions cannot operate simultaneously If the 8 C heating function was set in cool mode pressing the SLEE...

Page 16: ...ble replace the batteries Do not attempt to recharge the batteries Replace both batteries at the same time Do not throw batteries into fire they may explode signal sender battery Cover of battery box remove reinstall INFORMATION FOR THE CORRECT DISPOSAL OF BATTERIES IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2006 66 EC and amendments Directive 2013 56 EC Replace batteries when they are depleted At the ...

Page 17: ...t match for all units It may vary depending on the operating system used or the update in use Refer to the current version 5 If the access protection on your Router is active in the MAC Filter MAC address filter item enable the access to the network of the MAC address of the device Installation and use instruction 1 Frame the QR Code using a QR Code Reader or search for the EWPE SMART application ...

Page 18: ... same mail PASSWORD must have at least one capital letter symbols or special characters etc and numbers Repeat PASSWORD written above EUROPE country Open the app Make the registration before Access 3 Adding units Clicking on the icon of the little man opens a menu that includes among other things the Help function Follow the instructions that appear on your device to add the unit or add a new unit...

Page 19: ...n left After choosing the category of interest proceed with the reset of the unit Different unit reset systems can be chosen depending on the type of unit system and remote control with or without wifi key Follow step by step the operative instructions depending on the selected reset system ...

Page 20: ... buttons simultaneously for 1 second When the unit beeps it means that the reset has been successful NB The configuration must be done within 2 minutes If it does not happen within 2 minutes repeat the reset operation REMOTE CONTROL WITHOUT WIFI BUTTON MODE and TURBO Direct the remote control towards the unit Press the Mode Turbo buttons simultaneously for 10 seconds After the unit has twice produ...

Page 21: ...V 01 20 69 After performing the electrical reset of the unit and entering the information perform a search for the unit Search appliance and continue the configuration ...

Page 22: ...unctions In the Homepage click on the device you wish to control and access the operating interface of it 1 Select operating mode temperature and fan speed Mode 2 Temperature for each mode just slide your finger on the indicated temperature ...

Page 23: ...d for each mode just slide your finger on the fan symbol the adjustment possibilities vary depending on the mode 4 Set advanced functions Click Function Func in the lower left corner of the interface to enter the advanced settings ...

Page 24: ...swinging if available Sleep function Light on indoor unit display Temperature unit conversion Swing setting Clic Up down swing to turn the swing function on or off Click the arrow in the lower right corner of the icon to go to the next screen and set the swing level ...

Page 25: ... 01 20 73 List of Preselections Clic Timer Then clic and make adjustments Other functions 1 Homepage menu Click on the profile picture in the upper left corner of the homepage and set each menu function ...

Page 26: ... the group name to hhh and set up the devices in the group list When this group is working you can change the settings of the whole group 3 Home Management Click Home Management to create or manage a family system You can add new members to the family system of the registered account ...

Page 27: ...V 01 20 75 4 Help Press Help to view the instructions for EWPE SMART APP 5 Feedback Clic Feedback to send a feedback on the product ...

Page 28: ...etting from step 3 It is important to remember what is listed below 1 The WiFi function of the air conditioner takes about 1 minute to start 2 The air conditioner is equipped with memory function Emergency operation In the event of loss or failure of the remote control use the emergency button located under the indoor unit s front panel to turn the air conditioner on or off The unit will operate i...

Page 29: ...breaker plug and socket are in good working order 3 Check that the filters are clean 4 Check that the outdoor unit s support bracket is not damaged or corroded If it is contact the service centre 5 Check that the piping is not damaged After use checks 1 Disconnect the power supply 2 Clean the indoor unit s panel and filters 3 Check that the outdoor unit s support bracket is not damaged or corroded...

Page 30: ... a power cut Wait for the power to be restored Has the plug come loose Reinsert the plug Has the circuit breaker tripped or has the fuse blown Have the circuit breaker or fuse replaced by a qualified technician Is the wiring faulty Have it replaced by a qualified technician Was the unit restarted immediately after shutdown Wait 3 minutes and then restart the unit Is the setting on the remote contr...

Page 31: ...urning the unit off and on again Otherwise contact a qualified technician for assistance E8 Can be eliminated by turning the unit off and on again Otherwise contact a qualified technician for assistance C5 Contact a qualified technician for assistance F1 Contact a qualified technician for assistance F2 Contact a qualified technician for assistance N B In the event of other error codes contact a qu...

Page 32: ...e to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall At least 50cm At least 50cm At least 30cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruction At least 30cm Space to the wall Drainage pipe ...

Page 33: ...r or other foreign matter in the refrigerant circuit will cause increased system pressure or compressor failure resulting in damage When installing or relocating the unit do not charge refrigerant that does not conform to that indicated on the nameplate or unidentified refrigerant Otherwise it may cause abnormal operation or an accident When refrigerant needs to be recovered in case of transfer or...

Page 34: ...low produced by the outdoor unit will not annoy neighbours 2 The location should be well ventilated and dry the outdoor unit must not be exposed to direct sunlight or strong winds 3 The site should be able to support the weight of the outdoor unit 4 Check that the installation complies with the requirements of the dimensional drawing for installation 5 Choose a location out of the reach of childre...

Page 35: ...al limitations and customer requirements Check that in the selected location the unit can be accessed for servicing and cleaning the filters To install use the installation plate as a template to identify the exact position for the wall plugs and through hole in the wall The plastic casing has stoppers which if necessary can be removed to route the refrigerant lines and cables When operating in co...

Page 36: ...all plugs are not supplied but must be purchased on site Indoors Outdoors Step four outlet pipe The pipe can be brought out in various different directions right rear right left or rear left destra right Posteriore destra rear right sinistra left Posteriore sinistra rear left Once you have selected the direction of the outlet left or right drill the corresponding hole at the bottom destra right fo...

Page 37: ...torque Nm 6 35 15 20 9 52 35 40 tuboisolante insulating tube Wrap the indoor pipe and the joint of the connecting pipe with an insulating tube Then wrap with tape Step six install the condensate drain pipe Connect the drain pipe to the outlet pipe of the indoor unit Bind the joint with tape tuboisolante insulating tube tubo di uscita outlet pipe tubo di scarico drain pipe nastro tape N B Add an in...

Page 38: ... block cover and tighten the screws 5 Close the panel N B All wiring must be connected as shown on the unit s wiring diagram All indoor and outdoor unit cables must be connected by a qualified technician If the power cable is not long enough contact the supplier for a new one Do not attempt to extend it yourself For air conditioners equipped with a plug the plug must be easily accessible upon comp...

Page 39: ...mma di sigillatura rubber sealant gancio superiore upper hook gancio inferiore del telaio di montaggio a parete lower hook of wall installation frame N B Avoid bending the drain pipe too much in order to prevent clogging Outdoor unit installation For all connections refer to the wiring diagrams supplied with the unit If the outdoor unit was connected to a higher level than the one of the indoor un...

Page 40: ... can steer the condensation water Install the discharge fitting and the rubber gasket on the frame of the outdoor unit and connect a drain hose as shown in figure Keep sealed all open extremities of the pipes with a cap until the connection is completed Be sure not to let anything in the pipes or in the system such as dirt water etc The piping connected to the indoor and outdoor unit must be new R...

Page 41: ...rom the refrigerant circuit using a vacuum pump Vacuum pump Vacuum pump Twisting moment N m 35 40 60 65 45 50 Φ12 70 75 Φ19 Φ9 52 Diameter mm Φ16 1 Unscrew and remove the caps from the 2 way and 3 way valves 2 Unscrew and remove the cap from the service valve 3 Connect the vacuum pump hose to the service valve 4 Operate the vacuum pump for 10 15 minutes until an absolute vacuum of 10 mm Hg has bee...

Page 42: ...ert a magneto thermic switch with sufficient power and observe the following table Power circuit breaker 18K 16A 21K 24K 28K 36K 42K 25A To protect the unit against short circuits mount on the power line a magneto thermal omni polar switch IG curve C 250V with a minimum contact opening of 3mm Wrong connection of cable may cause malfunctions of the electrical components Once fixed the cables make s...

Page 43: ...V 01 20 91 X3MI ECO 52SH To the power supply To unit B Power cord To unit A connecting cable L connecting cable Handle ...

Page 44: ...To the power supply Power cord L To unit A To unit B connecting cable To unit C connecting cable connecting cable Handle Handle To the power supply To unit B To unit A connecting connecting cable cable To unit C connecting cable Power cord L ...

Page 45: ... 80SH X3MI ECO 105SH X3MI ECO 120SH Handle To the power supply To unit B To unit A connecting cable To unit C connecting connecting cable cable connecting cable Power cord L To I I I I I yellow b b b b E N D N C N B N A N ...

Page 46: ...ction or damage to components Are the gas valve and liquid valve of the connecting tube fully open The cooling heating capacity may be insufficient Have the length of the refrigerating tube and the amount of the refrigerant charge been registered It is not easy to decide the amount of the refrigerant charge to add Safety operation of flammable refrigerant Qualification requirement for installation...

Page 47: ...e there aren t any free flames near the outlet of the vacuum pump and that it s well ventilated Filling the refrigerator circuit Use refrigerant filling appliances specialized for R32 Make sure that different kinds of refrigerant don t contaminate one another The refrigerant tank should be kept upright when filling with the refrigerant Stick the label on the system after filling is finished Don t ...

Page 48: ...ng N B Improper extension of piping is the main cause of refrigerant leaks Proceed as shown below 1 Cut the pipe Check the length of the pipe based on the distance between the indoor unit and outdoor unit Cut the required pipe using a pipe cutter tubo pipe tagliatubi pipe cutter inclinato slanted irregolare uneven sbavatura burred 2 Remove burrs Remove burrs with a file ensuring they do not go int...

Page 49: ...e port again following the procedure described above superficie liscia smooth surface allargamento imperfetto defective expansion lunghezza uguale equal length inclinato slanted superficie danneggiata surface damaged fessurazione cracked spessore irregolare uneven thickness tubo di raccordo union pipe tubo pipe verso il basso tubo limatrice tubo di raccordo tubo lunghezza uguale allargamento imper...

Page 50: ...otential GWP 675 Do not release R32 into the atmosphere X3MI ECO 52SHB Kg 1 00 0 675 Tonn CO2 equiv X3MI ECO 61SH Kg 1 60 1 080 Tonn CO2 equiv X3MI ECO 71SH Kg 1 80 1 215 Tonn CO2 equiv X3MI ECO 80SH Kg 2 00 1 350 Tonn CO2 equiv X3MI ECO 105SH Kg 2 75 1 856 Tonn CO2 equiv X3MI ECO 120SH Kg 2 75 1 856 Tonn CO2 equiv ...