16.3 Operating conditions
Permissible temperature range
Hydraulic fluid °C
0...65 (note viscosity range)
Ambient temperature °C
0...50
CAUTION
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded
during operation.
Allow the filter unit to cool down before touching it.
Permissible viscosity range
mm
2
/s (continuous operation)
15 - 200
mm
2
/s (max. short-term operation)
(up to a total duration of 20 hours
during the period of use of the unit)
15 - 400
NOTE
Varying viscosity behavior
Viscosities of a medium are always temperature-dependent.
Admissible suction heights
m (max.) first use
1.0
m (max.) operating status
2.0
Resistant to environmentally friendly and petroleum based fluids.
Before use with synthetic fluids please contact the manufacturer.
Work position
Abitrarily, perferably standing
Mains fuse
230 V, 50 Hz, 10 - 16 Amps
FA 008 - 1180, -1380, -1680
16.4 Hydraulic circuit diagrams
Fig. 12: Hydraulic circuit diagram
1
Suction hose
5
Filter
2
Suction strainer
6
Clogging Indicator
3
Motor
7
Pressure limiting valve
4
Pump
8
Pressure hose
7
8
6
5
4
3
1
2