P44x/EN CM/E33
Commissioning
Page 34/54
MiCOM P441/P442 & P444
5.3.2
Distance scheme test (if validated in S1 & PSL)
5.3.2.1
Control
•
The type of distance scheme enable in S1
•
The DDB cells assigned for distance scheme
•
Ref to the description feature in P44x /EN AP item 2.4 & 2.5:
⇒
Settings in S1
⇒
DDB cells
⇒
Internal logic in A2.10 & A3.2
REMINDER: General equation to the tripping in distance protection
since
A2.9/A3.1 – From A2.10/A3.2 could be found in the Chap EN AP –
item 2.5
NOTE :
Before tests, control the input presence /Output in PSL (See chapter
AP section 6.2 & 6.3) linked to the selected teleaction scheme (DDB :
DistCR/Dist CS/).Control as well the I/O condition change (on LCD in
FAV in "system ")
Input :(PSL by default "P&C ")
Output : (PSL by default "P&C ")
WARNING
:
TAKE CARE ABOUT THE CHANGEMENT OF GROUP BY OPTOS
– IF SELECTED IN S1 (OPTO 1 & 2 IN THAT CASE SWITCHING GROUPS
BY
OPTOS)
– IF USED FOR SWITCHING GROUP (OPTO 1 & 2 MUST BE ABSENT
FROM THE PSL)
Opto Label 02
DIST Sig Send
DDB #033
DIST. COS
DDB #098
Opto Label 02
DDB #033
DIST. COS
DDB #099
Opto Label 01
DDB #032
DDB #096
Opto Label 01
DDB #032
DEF. Chan Recv
DEF. Chan Recv
DDB #097
P3021ENa
DDB #178
DIST Sig Send
DDB #207
1
Relay Label 05
DDB #004
Pick-Up
0
0
Signal Send (Dist + DEF)
1.
From MiCOM S1, select a one of the mode in the table 5.6 in P44x /EN AP (last
column).
2.
Implement the indicated default in the panel first column , The carrier signal input
being activated (with TAC).
3.
Check the tripping contact have been energised at the issue of the indicated time
delay indicated in the same column (With TAC).
4.
Repeat step 2 and 3 but without teleaction input and by checking the indicated time
delay in the panel’s 2nd column (Without TAC).
Repeat step 2 and 4 for the others zones defaults by checking, whatever the teleaction input
condition, the associated time delays to every zones are not modified (according to the 4th
column equations)
NOTE :
– TAC can be simulated by inverting the opto.
– TAC transmissions can also be checked by generating
defaults according to the 3rd column.
– To make easy the relay I/O control condition, the LEDs
affectation in PSL can be modified. Another possibility is in S1 –
See Testing tools (monitor bit control).
Summary of Contents for MiCOM P441
Page 1: ...MiCOM P441 P442 P444 Numerical Distance Protection VC2 x Technical Guide P44x EN T E44...
Page 2: ......
Page 4: ...P44x EN T E44 Technical Guide Page 2 2 MiCOM P441 P442 P444 BLANK PAGE...
Page 5: ...Pxxxx EN SS C11 SAFETY SECTION...
Page 6: ......
Page 8: ...Pxxxx EN SS C11 Page 2 10 Safety Section BLANK PAGE...
Page 17: ...Update Documentation P44x EN AD E44 MiCOM P441 P442 P444 UPDATE DOCUMENTATION VERSION C2 X...
Page 18: ......
Page 22: ...P44x EN AD E44 Update Documentation Page 4 82 MiCOM P441 P442 P444 BLANK PAGE...
Page 23: ...Update Documentation P44x EN AD E44 MiCOM P441 P442 P444 Page 5 82 P44X EN IT E33 INTRODUCTION...
Page 24: ......
Page 34: ......
Page 44: ......
Page 96: ...P44x EN AD E44 Update Documentation Page 78 82 MiCOM P441 P442 P444 BLANK PAGE...
Page 98: ......
Page 100: ...P44x EN AD E44 Update Documentation Page 82 82 MiCOM P441 P442 P444 BLANK PAGE...
Page 101: ...Introduction P44x EN IT E33 MiCOM P441 P442 P444 INTRODUCTION...
Page 102: ......
Page 104: ...P44x EN IT E33 Introduction Page 2 24 MiCOM P441 P442 P444 BLANK PAGE...
Page 127: ...Relay Description P44x EN HW E33 MiCOM P441 P442 P444 RELAY DESCRIPTION...
Page 128: ......
Page 132: ...P44x EN HW E33 Relay Description Page 4 44 MiCOM P441 P442 P444 BLANK PAGE...
Page 152: ...P44x EN HW E33 Relay Description Page 24 44 MiCOM P441 P442 P444 Example isolated AC fault...
Page 153: ...Relay Description P44x EN HW E33 MiCOM P441 P442 P444 Page 25 44...
Page 173: ...Application Notes P44x EN AP E33 MiCOM P441 P442 P444 APPLICATION NOTES...
Page 174: ......
Page 180: ...P44x EN AP E33 Application Notes Page 6 220 MiCOM P441 P442 P444 BLANK PAGE...
Page 357: ...Application Notes P44x EN AP E33 MiCOM P441 P442 P444 Page 183 220...
Page 364: ...P44x EN AP E33 Application Notes Page 190 220 MiCOM P441 P442 P444 BLANK PAGE...
Page 394: ...P44x EN AP E33 Application Notes Page 220 220 MiCOM P441 P442 P444 BLANK PAGE...
Page 395: ...Technical Data P44x EN TD E33 MiCOM P441 P442 P444 TECHNICAL DATA...
Page 396: ......
Page 400: ...P44x EN TD E33 Technical Data Page 4 30 MiCOM P441 P442 P444 BLANK PAGE...
Page 427: ...Installation P44x EN IN E33 MiCOM P441 P442 P444 INSTALLATION...
Page 428: ......
Page 430: ...P44x EN IN E33 Installation Page 2 10 MiCOM P441 P442 P444 BLANK PAGE...
Page 438: ...P44x EN IN E33 Installation Page 10 10 MiCOM P441 P442 P444 BLANK PAGE...
Page 439: ...Commissioning P44x EN CM E33 MiCOM P441 P442 P444 COMMISSIONING...
Page 440: ......
Page 494: ...P44x EN CM E33 Commissioning Page 54 54 MiCOM P441 P442 P444 BLANK PAGE...
Page 496: ......
Page 498: ...P44x EN RS E33 Commissioning Test Record Sheets Page 2 10 MiCOM P441 P442 P444 BLANK PAGE...
Page 507: ...Connection Diagrams P44x EN CO E33 MiCOM P441 P442 P444 CONNECTION DIAGRAMS...
Page 508: ......
Page 510: ...P44x EN CO E33 Connection Diagrams Page 2 12 MiCOM P441 P442 P444 BLANK PAGE...
Page 520: ...P44x EN CO E33 Connection Diagrams Page 12 12 MiCOM P441 P442 P444 BLANK PAGE...
Page 521: ...Courrier Data Base P44x EN GC E44 MiCOM P441 P442 P444 CONFIGURATION MAPPING...
Page 610: ...Courier Data Base P44x EN GC E44 MiCOM P441 P442 P444 DEFAULT PROGRAMMABLE SCHEME LOGIC PSL...
Page 615: ...Menu Content Tables P44x EN HI E44 MiCOM P441 P442 P444 MENU CONTENT TABLES...
Page 616: ......
Page 624: ......
Page 626: ......
Page 634: ...P44x EN VC E44 Hardware Software Version Page 8 8 MiCOM P441 P442 P444 BLANK PAGE...
Page 635: ......