CLI Manager
31
New PHY Group Mode: T10
Group-1: C0, Slot: 1, 2, 3, 4, 5, 6
Value: 0x00000000000FFC00
Current PHY Group Mode: T10
Group-1: C0, C1, C2, C3, C4 Slot: 1, 2, 3, 4, 5, 6, 7, 8
Value: 0x0000000FFFFFFFFF
//Set the cable1 and cable2 and slot 7 to slot 8 as group 2
CLI>gr dev 2 c1, c2 7 8
New PHY Group Mode: T10
Group-1: C0, Slot: 1, 2, 3, 4, 5, 6
Value: 0x00000000000FFC00
Group-2: C1, C2, Slot: 7, 8
Value: 0x000000000FF003FF
Current PHY Group Mode: T10
Group-1: C0, C1, C2, C3, C4 Slot: 1, 2, 3, 4, 5, 6, 7, 8
Value: 0x0000000FFFFFFFFF
CLI>st
Power Cycle to reboot
CLI>gr
Current PHY Group Mode: T10
Group-1: C0, Slot: 1, 2, 3, 4, 5, 6
Value: 0x00000000000FFC00
Group-2: C1, C2, Slot: 7, 8
Value: 0x000000000FF003FF
• SYS Command
The sys command is used to view the expander’s information.
Typical information includes: vendor, model name, serial/unit
number, expander port number, product revision, chip name/chip
revision, customer code, manufacture data revision and work
time.
Syntax
CLI>sys