Liite 2 (12)
12
Maintenance procedures
High voltage disconnect handle fuse attachment and detachment.
Removing the handle fuse breaks the high voltage path making maintenance
safer. The handle fuse must be detached every time when the covers are
opened and the high voltage system is visible.
1. Press the button in the notch to release the first lock.
2. Pull the handle until it stops.
3. Press the second lock to release it.
4. Pull the handle until it stops.
5. Pull the handle fuse away from the base.
6. To attach the handle fuse slide it in the place.
7. Push the handle until both locks engage. Ensure proper mounting by pulling
the handle fuse from the base.
3.
4.
6.
5.
7.
1.
2.