The snowmobile does not react to the key
1. Faulty battery or broken fuse
If the snowmobile reacts to the charging cable, check main fuses F1.1
and F2.1 and 12V system battery. Replace if faulty. Please refer to page
17.
Unidentified fault
Contact manufacturer
Plugging the charge connector does not initiate the charging
1. Power pack poorly attached
Check the connectors in power pack. For instructions please refer to
page 13.
2. Fault in wall socket or charging station
Check the wall socket or charging station for faults
3. Faulty charger
Contact manufacturer
Stays at ”Changing mode” while starting up
1. Traction system master switch
Make sure that the Traction system master switch is turned to ”ON”
position. The switch can be found from the rear end of the power pack.
Turn the key clockwise to turn it on.
2. Faulty controller
Contact manufacturer
”Changing mode” stays while cranking but returns to default screen.
1. Kill switch in ”OFF” position or tether removed.
Pull kill switch to position ”ON” or connect tether
2. Insulation monitoring device detects an error and GFD-led is lit.
Contact manufacturer
Summary of Contents for eSled CSC 2015
Page 29: ...Liite 1 3 9 1 eSled CSC 2015 Operator s manual 26...
Page 38: ...Liite 1 12 12 Kuvio 3 Suositeltu tunnistehierarkiarakenne tavallisessa kokoonpanossa...
Page 44: ...Liite 1 18 18 Kuvio 6 Esimerkki Akuston datalehti...
Page 46: ...Liite 1 20 20 Kuvio 7 Esimerkki vaatimusm ritys...
Page 53: ...Liite 2 0 eSled CSC 2015 Operator s manual ARCTIC POWER 11 16 2015 Version 0_5_0...
Page 78: ...Liite 2 25...