OPERATION
26
NOTE:
“Parameter selection keys” and “Adjusting dial” can be used only in the welding process.
“Rod electrode welding key” and “Adjusting dial” can be used only on MMA mode.
4.3 Remote control
1-3 CURRENT SET
:
They are factory set, can’t be changed. If they are changed, the welder may not work.
4 FACTORY TEST
:
When it is ON, the welder is on debug state.
5 FOOT_REMOTE BOX SELECT
:
When it is ON, the pedal control can be used
;
When it is OFF, the remote box can be used.
Torch switch control current can be used both ON and OFF.
4.3.1 Pedal switch control
●
Plug into the fourteen-lead aero-socket of pedal switch. Welder will identify the pedal switch, the welding current knob
on the front panel will can’t use
,
and only 2T can be selected.
●
Set adjustment knob to max current on pedal and use pedal to provide amperage required.
●
The eighth and ninth of the fourteen-lead aero-socket is the torch switch; The first and second of the fourteen-lead
aero-socket is short circuit; The third
、
fourth and fifth of the fourteen-lead aero-socket is pedal adjustable resistance.
Water cooling
Gas cooling