Archgard NorthFire-DVT36E Installation And Operating Instructions Manual Download Page 1

 

 

 

MODEL NORTHFIRE  

DV36-E (Top Vent) 

DIRECT VENTED BUILT-IN  

GAS FIREPLACE  

FOR USE WITH NATURAL GAS AND PROPANE 

 
 

INSTALLATION AND OPERATING INSTRUCTIONS 

FOR YOUR SAFETY 

 

DO NOT store or use gasoline or any other flammable vapors or liquids in the vicinity 
of this or any other appliance 

 

IF YOU SMELL GAS: 
-   Do not try to light any appliance.  
-  Open windows. 
-  Do not touch electrical switches. 
-  Extinguish any open flame. 
-  Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier’s 

instructions. 

-  If you cannot reach the gas supplier, call the fire department. 

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND 

OPERATING THE APPLIANCE 

 

WARNING:

 

Improper installation, adjustment, alteration, service or maintenance voids 

all the manufacturer’s warranties and may cause property damage, personal injury or 
loss of life. 

 

Installation and service must be performed by a qualified installer, service agency or the 
gas supplier. 

 Installer, please leave this manual with the appliance owner for future reference. 

WARNOCK HERSEY 

CERTIFIED FOR CANADA AND USA 

NOT FOR USE WITH SOLID FUEL 

200-0055            22JAN02 

f i r e - p a r t s . c o m

Summary of Contents for NorthFire-DVT36E

Page 1: ...phone Follow the gas supplier s instructions If you cannot reach the gas supplier call the fire department PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING AND OPERATING THE APPLIANCE WARNING Imp...

Page 2: ...tions 5 13 Operation Instructions 14 15 Maintenance 16 Trouble Shooting Instructions 17 18 Servicing 19 20 Important Information Form 21 Warranty 22 Parts and Accessories 23 Allowed Termination Locati...

Page 3: ...njoyment CAUTION Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temp...

Page 4: ...in Canada Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C...

Page 5: ...CONTROL TOP LOUVERS GLASS DOOR APPLIANCE DIMENSIONS FRONT VIEW 36 1 4 23 1 2 37 3 4 TOP VIEW SIDE VIEW FRONT VIEW 3 1 2 Except for the vent connector locations the rear vented DVR36H and top vented D...

Page 6: ...ble for venting See APPENDIX A ALLOWABLE TERMINATION LOCATIONS VENT TERMINATION 1 See ALLOWABLE TERMINATION LOCATIONS diagram page 24 to establish a suitable vent termination location 2 In heavy snowf...

Page 7: ...nt 6 FRAMING DIMENSIONS 36 1 4 16 39 1 2 28 36 1 4 56 36 1 4 31 16 If more rigidity is required A stud may be added to the back of the top nailing flange after the fireplace is installed TERMINATION F...

Page 8: ...bserve the venting chart given in this manual 5 Use a vent spacer between the inside and outside flex vents at every 3 ft intervals 6 Never slope horizontal running vents downwards 7 Maintain at least...

Page 9: ...rmed lip Restrictor Placement WARNING These restrictors are only to be installed in the vent system if the vent exceeds 7 in vertical height See below which restrictor is required Installing them unde...

Page 10: ...NTAL LENGTH from center of flue outlet to base of termination VERTICAL HEIGHT from bottom of appliance to center of termination 7 ft Venting in this area requires a vent restrictor plate 1 5 ft 7 ft 9...

Page 11: ...he appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or...

Page 12: ...re two latches under the firebox Undo the latches swing the bottom of the door away from the appliance and then lift the door off the top retaining tabs Carefully place the door in a safe location whe...

Page 13: ...is provided with the heater Place the fibre coals on the burner tray surrounding the burner DO NOT place fibre coals on the burner itself Tear ember wool into 1 2 to 3 4 diameter ember pieces and plac...

Page 14: ...ce and into the bottom of the gas fireplace Be sure to connect a grounding wire to the side of gas fireplace Use any screw hole on the side for this purpose Slide the thermal snap switch into the fork...

Page 15: ...the appliance area for gas Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor IF YOU SMELL GAS follow the instruction on the front cover of this ma...

Page 16: ...INTERLOCK for proper lighting of pilot Press slightly and turn control knob counterclockwise 4 to PILOT position depress control knob and light pilot by repeatedly pressing the sparker Venting of air...

Page 17: ...tside the house wearing a dust mask The logs are very fragile take care not to break them After cleaning the logs must be replaced as per the instructions in this manual When replacing glass door ensu...

Page 18: ...as valve may be defective Pilot will not remain on after being lit 1 Press the control knob all the way in 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the pi...

Page 19: ...primary air by opening the primary air shutter 2 Check for proper placement of the logs and branches See that section in the instruction manual 3 Check for obstruction of the burner ports by the ember...

Page 20: ...shutter screw with a Philips screwdriver Rotate air shutter with a flat tip screw driver The primary air opening size can be easily seen with a flashlight Tighten the air shutter screw after adjustmen...

Page 21: ...ssembly plate to the appliance Gently lift the assembly up and tilt the back up to clear the front of the valve from the opening Replacing the assembly is the reverse of the above instructions Disconn...

Page 22: ...SS PHONE NUMBER COMPANY NAME ADDRESS PHONE NUMBER APPLIANCE MODEL NUMBER NORTHFIRE DVT36E SERIAL NUMBER GAS TYPE NATURAL GAS LPG VALVE TYPE SIT 820 DATE PURCHASED INSTALLATION INSTALLER NAME DATE INST...

Page 23: ...doubt OBTAINING WARRANTY SERVICE To obtain warranty service the consumer shall return the defective part to the original selling dealer transportation prepaid along with the serial number of the appl...

Page 24: ...EMP 16 150x28 843 DV36E 1 EA 308 0005 PIEZO IGNITOR C W NUT JBS 66270 003 1 EA 308 0007 PIEZO IGNITOR FOR MOUNTING ON VALVE SIT 1 EA 308 0022 VALVES DEXEN NG 3 5 WC 3 8X3 8 6003S 1 EA 308 0054 PILOT A...

Page 25: ...24 fire parts com...

Page 26: ..._________________________________ Telephone ______ ______ _________ Dealer s Name Address ______________________________________________________ ______________________________________________________...

Reviews: