Archgard 31-DVIM33C-2 Installation, Operation And Maintenance Manual Download Page 1

31-DVIM33C-2

GAS FIRED VENTED ROOM HEATER 

(DIRECT VENT)

S/N 200326 AND UP

ARCHGARD FIREPLACE PRODUCTS

7116 Beatty Drive

Mission, BC V2V 6B4 Canada

200-1234-06

October 18 2018

English and French Installation Manuals available through your 

local dealer or visit our website at: 

www.archgard.com

Les manuels d'installation en anglais et en français son 

disponibles chez votre détaillant local ou en visitant notre site 

web: 

www.archgard.com

INSTALLER

:  LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER

:  RETAIN THIS MANUAL FOR FUTURE REFERENCE

This appliance may be installed in an aftermarket permanently 

located, manufactured home (USA only) or mobile home where 

not prohibited by local codes.

This appliance is only for use with the type of gas indicated on 

the rating plate. This appliance is not convertible for use with 

other gases, unless a certified kit is used. 

WARNING: If the information in these instructions is not 

followed exactly, a fire or explosion may result, causing 

property damage, personal injury or loss of life.

INSTALLATION, OPERATION, AND 

MAINTENANCE MANUAL

Do not store or use gasoline or other flammable vapors or 

liquids in the vicinity of this or any other appliance. 

WHAT TO DO IF YOU SMELL GAS:

• 

Do not try to light any appliance

• 

Do not touch any electrical switch; do not use any phone in 

your building

• 

Immediately call your gas supplier from a neighbors phone.

• 

Follow the gas suppliers instructions

• 

If you can not reach your gas supplier, call the fire 

department

Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

WARNING:

 If the information in this manual is not followed 

exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life.

70.26%

Based on CSA P.4.1-09

Summary of Contents for 31-DVIM33C-2

Page 1: ...is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property dam...

Page 2: ...Instructions 16 Approved Terminations 16 Venting Instructions 999 INS TK 17 Using a Co linear to Coaxial Adapter 18 Optional Wall Switch Or Thermostat 19 Fan Wiring Diagram 19 Vent Restrictor Installa...

Page 3: ...means that it is less expensive to operate Adjustable Fan Speed Each 31 DVIM33C 2 comes complete with 6 level adjustable speed controlled circulation fan Adjustable Flame The flame aesthetics and heat...

Page 4: ...a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not store or place combustibles gasol...

Page 5: ...49 1 in Canada Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code C...

Page 6: ...he rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details This appliance is not convertible...

Page 7: ...ting screw on each side and swinging the panels out and replacing the screws They can also be disconnected and placed remotely within the limits of the gas connections and electrical wiring making sur...

Page 8: ...NLY Never attempt to install the appliance into a combustible enclosure If the information in these instructions are not followed exactly a fire or explosion may result causing property damage persona...

Page 9: ...fireplace flue damper A must be fully blocked open or removed for installation of the gas fireplace insert The fireplace and fireplace chimney must be clean and in good working order and constructed o...

Page 10: ...se only parts specifically approved with this appliance may result in property damage or personal injury NOTE Mantle depth maybe increased decreased 1 25 4 mm for each 1 25 4 mm change in correspondin...

Page 11: ...damage or personal injury All specified clearances must be maintained from the top surface of carpeting tile etc Combustible Zone NOTE All specified clearances must be maintained from the top surface...

Page 12: ...manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such da...

Page 13: ...NUMBERS 31 CKMLP for LP gas and 31 CKMNG for Natural Gas KIT INCLUDES 1 Gas conversion label 303 0128 1 Burner orifice 301 0068 51 51 DMS for LPG 301 0068 33 33 DMS for NG 1 Gas type Label 1 SIT 820...

Page 14: ...w modulating pressure regulator assembly to the valve using the screws provided in the conversion package Install the LP identification label to the valve found in kit Affix Archgard Manufacturer s la...

Page 15: ...check the hearth of the fireplace to see if it is level with the front of the fireplace If it is not measure the depth of the hearth Loosen the three screws of the leveling L bracket at the back of t...

Page 16: ...he appliance to the termination The flue length must be a minimum of 10 3 05 M and a maximum of 40 12 2 M The exhaust vent restrictor provided with this appliance must only be used by installing it on...

Page 17: ...llar clamp and stove cement provided with the kit DO NOT USE SILICONE 7 Seal and attach the end of the flex liner marked Air Intake to the collar marked Air Intake on the appliance with the collar cla...

Page 18: ...must conform with the local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the US or Installation Code CAN CGA B149 1 in Canada Electrical conne...

Page 19: ...GA 20 Ft 6 9 M 20 GA 12 Ft 3 65 M 22 GA 9 Ft 2 74 M PILOT ASSEMBLY A ELECTRODE N A B THERMOPILE 308 0056 C PILOT HOOD N A D THERMOCOUPLE 308 0122 Fan Wiring Diagram The fan disc is factory set to clos...

Page 20: ...ptions available are dependent upon the control panel configuration See Control Panel Locations regarding configura tion Shallow surround options are not available on a unit with Controls Out configur...

Page 21: ...Fire Bead Installation WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or...

Page 22: ...ep burner ports clear of blockage i e flat surfaces of the rocks to create an enjoyable burning fire If the ports are covered it may cause soot build up that will affect the operation and maintenance...

Page 23: ...the bottom of the door lift up on the top of the door until it engages 6 Push down on the top of the door to ensure the door is seated all the way down on the catches 7 Pull the finger rings out and d...

Page 24: ...STALLED PRIOR TO SCREEN TO AVOID POSSIBLE DAMAGE OR INJURY Identify the top and bottom of the screen Ensure the screen retainer tabs are aligned along the bottom of the screen Insert the hooks in the...

Page 25: ...me to ensure that the fan is working correctly After the system has been checked and confirmed that the fan is in working order refer to the instructions for FIRST FIRE located in this manual As a rem...

Page 26: ...26 Operation Operation Lighting Instructions On Rating Plate...

Page 27: ...dequate combustion and ventilation air Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light...

Page 28: ...h logs with any liquid While the logs are removed check that all burner openings are not obstructed and it is recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any li...

Page 29: ...ge personal injury or loss of life All servicing should be conducted with the appliance cold All replacement parts must be authorized by Archgard for suitability Adjusting Primary Air NOTE Fig 28 A is...

Page 30: ...ed OUT See Below 3 Loosen the set screw inside the tap with a screwdriver 4 Connect a 1 4 6 mm rubber tube to the tap post and a manometer 5 Verify that the readings obtained are within specs as shown...

Page 31: ...ACCESS FROM THE FRONT 1 Remove the glass door Follow GLASS DOOR REMOVAL instructions within this manual 2 Remove the BURNER MEDIA 3 Remove the pan burner Follow instructions for CHANGING MAIN BURNER...

Page 32: ...ot immediately after you have shut off the pilot you have to wait 5 minutes for the valve to reset safety system built into the valve 4 Check to see if the pilot flame is large enough to reach and sur...

Page 33: ...ith flames lifting off the burner at the ends 1 Too much primary air Reduce primary air by closing the primary air shutter During cold temperatures some flame lifting may occur during start up Convect...

Page 34: ...switch closes the electrical circuit that allows the fan to turn on This is a normal sound Q I hear a ticking cracking or pinging sound when my fireplace is running and after it is turned off A The di...

Page 35: ...ncludes the items listed below EA 308 0122 Thermocouple EA 308 0056 750 Mv Thermopile EA 733 0027 Pilot Shield EA 831 0051 Burner Assembly Contemporary Type EA RF 305 0024 Replacement Cross flow Fan 1...

Page 36: ...If you cannot solve the problem contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase...