SBS COSMOS
REFRIGERATOR
10.01.2014 / REV NO: 03
136
Sensitivity: Public
14.16. Condensation in the form of drops are observed on the water
dispenser area
Condensation
in the form of
drops are
observed on
the water
dispenser
area
Display will be adjusted to ice supply and
trigger will be pressed and held. After the
flap opens and ice is obtained, trigger will
be released. Flap should be closed in a
way not to take air in. Check and/or
replace it.
YES
Ice pouring mouth flap may be
ajar.
NO
Display is removed and
position of the water pipe will be
checked. If it is to touch a place, its
position will be corrected or the
group will be replaced.
NO
Water pipe may be
touching somewhere.
Run the refrigerator and
wait for at least 1 day.
Note: In very humid environments, condensation is normal along
the water line especially at the corners. This is not a problem.