13.10.
Cooling failure due to electrical issues
Refrigerator does not cool
Enter service test and operate
compressor. Check if it is running.
Cooling
failure due
to electrical
issues
Operation is successful
Yes
No
Yes
Is compressor
running?
Is Freezer fan
running?
Enter service test and operate freezer
fan. Open Freezer door and hold a
magnet to the reed switch with your
hand and check if the fan is running.
Enter service test and operate freezer
fan. Open Freezer door and hold a
magnet to the reed switch with your
hand and check if the fan is running.
Is Freshfood fan
running?
Remove the connector of the cables
entering the body from the
compressor’s side. Use a crocodile clip
to attach Brown and Black cables and
check if compressor runs after re-
energizing
Is compressor
running?
Yes
No
Replace freezer fan
Go to Step 2
Go to Step 3
Replace Freshfood fan
Yes
No
Yes
No
Step-1
Step-2
Step -3
Measure thermic contacts
and replace the ones with
open circuit. Replace the
compressor if it still does
not operate.
Replace condenser fan
Is Condenser fan
running?
Yes
No
Replace control board
If error persists, see guidelines about cooling system
Summary of Contents for BEKO COSMOS
Page 49: ...SBS COSMOS REFRIGERATOR 07 11 2018 REV NO 01 49 Sensitivity Public...
Page 155: ...SBS COSMOS REFRIGERATOR 10 01 2014 REV NO 03 25 Sensitivity Public...
Page 165: ...SBS COSMOS REFRIGERATOR 10 01 2014 REV NO 03 35 Sensitivity Public...
Page 174: ...SBS COSMOS REFRIGERATOR 10 01 2014 REV NO 03 44 Sensitivity Public...
Page 183: ...SBS COSMOS REFRIGERATOR 10 01 2014 REV NO 03 53 Sensitivity Public...
Page 222: ...SBS COSMOS REFRIGERATOR 10 01 2014 REV NO 03 92 Sensitivity Public...
Page 268: ...SBS COSMOS REFRIGERATOR 10 01 2014 REV NO 03 138 Sensitivity Public 15 2 Service Test...