11.1.3.
Omnia Tests
Time Measurement
Component to be Controlled
0.5
2,3
FF Heater
0.4
4.2
FF Fan
4.4
6.2
Ionizer
4.4
6.2
Blue Ray
6.4
8,2
Defrost Heater
6,6
10,2
Frz Fan
10,4
12,2
FF Illumination
12.4
14.2
FRZ Illumination
14.4
16,2
Icematic Valveı
14,6
18.2
Condenser Fan
18,3
20,1
Water Pipe Heater
20,3
Compressor
Note:
Once the power is supplied, display version-revision info and then control board version-
revision info is shown on the display.
9.5.
Hot start condition:
If Freezer Eva >= +10C and Fridge Eva>= +10C, compressor keeps running after the
production test.
If not, compressor stops after the production test and main cooling cycle begins.