SBS COSMOS
REFRIGERATOR
10.01.2014 / REV NO: 03
116
Sensitivity: Public
13.7. E9 Icematic motor error
E9 Error flashes
In service test, rotate icematic motor in
pouring direction. Check if there is 12V
at control card motor socket (KN4) pins
7 and 8.
Replace Icematic
E9:
Icematic
Motor
Error
Turn on the refrigerator
Operation is successful
Yes
No
Yes
Is there 12V?
Replace control board
In service test, rotate icematic motor in
correcting direction. Check if there is
12V at control card motor socket (KN4)
pins 7 and 8.
No
Yes
Is there 12V?
Replace Icematic
Replace control board