E8 Error flashes
Check cables connected to control
board sensor socket (KN4) pins 14 and
15
Use a multimeter to measure sensor
resistance at KN4 pins
14 and 15 of control board and check if
the value is between 5K and 200K
Replace control board
Referring to Sensor replacement SUF,
replace the sensor
Yes
No
E8:
Icematic
Air
Sensor
Error
Turn on the refrigerator
Operation is successful
If cables are disconnected, re-connect
them, turn on the refrigerator and check
Yes
No
Yes
Any errors on
display?
Is the value suitable?