SBS COSMOS
REFRIGERATOR
10.01.2014 / REV NO: 03
111
Sensitivity: Public
E2 Error flashes
Check cables connected to control card
sensor socket (KN6) pins 3 and 4
Use a multimeter to measure sensor
resistance at KN6 pins
3 and 4 of control board and check if the
value is between 5K and 200K
Replace control board
As the sensor is enclosed in
polyurethane, it cannot be replaced
Yes
No
E2:
Fridge
Evaporator
Sensor
Error
Turn on the refrigerator
Operation is successful
If cables are disconnected, re-connect
them, turn on the refrigerator and check
Yes
No
Yes
Any errors on
display?
Is the value suitable?