SBS COSMOS
REFRIGERATOR
10.01.2014 / REV NO: 03
110
Sensitivity: Public
E1 Error flashes
Check cables connected to control card
sensor socket (KN6) pins 7 and 8
Use a multimeter to measure sensor
resistance at KN6 pins
7 and 8 of control board and check if the
value is between 5K and 200K
Replace control board
Referring to Sensor replacement SUF,
replace the faulty sensor
Yes
No
E1:
Freezer
Evaporator
Sensor
Error
Turn on the refrigerator
Operation is successful
If cables are disconnected, re-connect
them, turn on the refrigerator and check
Yes
No
Yes
Any errors on
display?
Is the value suitable?
13.3. E2 Fridge evaporator sensor error