14.13. Refrigerator does make ice
Refrigerator
does not make
ice.
Water does not arrive
to the icematic.
Remove the water pipe from
the water valve and discharge
the water to a container for 1-2
minutes. Attach
the pipe again
and check the system.
YES
Water pipe may
have air in it.
NO
Give air to the system and
check gas leakage with
foam sponge.
YES
Gas leakage in the
refrigeration system.
NO
Check
the
inside
of the
refrigerator
and/or
replace it.
YES
NO
Ice-making time may change
according
to the ambient
temperature. At the high
ambient temperatures and
in frequent opening/closing
of the door, extension of this
time is normal.
Water valve pump does not
pump water to the system.