Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
26
【
F6
】
, then the system immediately stops preheat to begin the next step of cutting, and records
the preheat time of 50 seconds, the system automatically thinks that users need preheat time
of 50 seconds, the next preheat after the null cutting when the preheat time becomes 50
seconds.
In the preheat process, each press the F7 key, preheat time increases by 15 seconds and
the preheat time maintains the increased value till incision ending of this time.
For example: The original system sets the preheat time of 60 seconds after the null cutting,
during the system countdown, each press F7, on the interface the countdown increases by 15
seconds, and the next time you need to preheat, the initial preheat time be 75 seconds.
3.8 Perforation Point Selection
Before you start cutting or cutting is paused, the function key prompt F8 is "select new
pierce", then press F8, the system will prompt:
FLSK F2200B
Version
3.3.71.1
Speed:
00000
File:
SHAPE_43.TXT
Status:
Stop
Current Line/Hole:
00000/00000
+X:500.00 -X:0.00 +Y:500.00 -Y:0.00
6: G01 X0 Y500.00
7
:
G01 X500.00 Y0
X
:
+000000.0
Y
:
+000000.0
Manual
【
F
】
StepMov
StepDis
【
G
】
5.00 Flame Cu
【
M
】
CutSpeed
【
X
】
1000.00 Kerf
【
N
】
1.20
ManualSpeed
【
Y
】
3000.00 Angle 0.00
Jump to new pierce?
ENTER: sure ESC: cancel
●
Ignition s
●
LowHeat s
●
HighPreheat s
●
Pierce1 s
●
Pierce2 s
●
Pierce3 s
●
TorchUp s
●
TorchDn s
●
THC En
●
Blow s
F1 Back
F2 Demo
F4
Speeddown
F5
Speedup
F6
Preheatdown
F7
Preheatup
F8
JumptoPierce
F3 GoBack
Fig. 3.6 select new pierce