Non-Touch Th
ermometer
User Manual
ARC Devices Ltd.
Copyright ARC Devices Ltd. 2016
Page 1: ...Non Touch Thermometer User Manual ARC Devices Ltd Copyright ARC Devices Ltd 2016 ...
Page 2: ...p To ensure the best results with your ARC InstaTemp thermometer please be sure to read the following operational and procedural manual carefully If you give this device to another adult it is vital that you also pass on this user manual The ARC InstaTemp is a sophisticated technologically advanced electronic medical device that has been carefully engineered to quickly and accurately measure human...
Page 3: ...it LCD Display Screen Remove protective label prior to use Temperature Range Indicator Light Activation Button Internal non removable non replaceable batteries are included ARC InstaTemp GETTING TO KNOW The ARC InstaTemp 3 ...
Page 4: ...Fahrenheit F or Celsius C The temperature reading will be displayed on screen for 4 seconds Turns off automatically when not in use Fast temperature readings that meet the ASTM standard LED display temperature range indicator system Green Orange Red Low battery indicator Features 1 2 3 4 5 6 7 8 GETTING TO KNOW The ARC InstaTemp 4 ...
Page 5: ...w these simple steps Press and release the activation button to get a reading Once the reading appears on screen in Fahrenheit press and release the activation button again the reading will automatically change to Celsius Repeat to change back OPERATION CHANGING ºF TO ºC 5 ...
Page 6: ... temperature immediately after he she has been exposed to really cold or hot climates or has drunk a hot or cold liquid as it may temporarily change the surface temperature of the skin In these instances wait 20 minutes before taking a temperature reading Do not touch the lens of the sensor It is the most delicate part of the ARC InstaTemp Before attempting to take a temperature reading OPERATION ...
Page 7: ...to and pointing directly at the center of the forehead at the area above the eyebrows and between the eyes when taking a temperature Hold the ARC InstaTemp in position and press and release the activation button once Hold the thermometer in position until the display is illuminated and a temperature reading is displayed on the screen OPERATION TAKING A TEMPERATURE 0 5 1 25 1 3cm Point and Click 7 ...
Page 8: ...depending on the temperature measurement detected See the tables on the following page for details of the temperature ranges Should you wish to take a second reading wait for 5 seconds and repeat Do not hold the activation button between measurements Temperature Range Indicator System OPERATION TAKING A TEMPERATURE 8 ...
Page 9: ...nge FAHRENHEIT F D i s p l a y R e a d o u t Note a red indicator light may mean very hot or very cold Outside the measurable range 89 5 109 1 F 32 42 8 C the screen shows or as applicable OPERATION UNDERSTANDING THE TEMPERATURE RANGE 9 CELSIUS C 42 8 C 38 00C 42 80C 37 20C 38 00C 36 00C 37 20C 35 00C 36 00C 32 00C 35 00C 32 C Temp in C Temp in C Temp in C Temp in C Temp in C ...
Page 10: ...utside the device s measurement range i e 109 1 F 42 8 C Reading The LCD will display This indicates that the temperature which the thermometer has measured is outside the device s measurement range i e 89 5 F 32 C Above 109 1º F 42 8 C Below 89 5º F 32 C OPERATION TEMPERATURE OUTSIDE MEASUREMENT RANGE 10 ...
Page 11: ... after the button is pressed then the battery has depleted and your thermometer needs to be replaced An Error message indicates an internal problem with the thermometer If an Error message is displayed please contact ARC Devices or your distributor Contact info on the final page of this document Indication Meaning OPERATION OTHER SCREEN INDICATIONS 11 ...
Page 12: ...rature measurement failed due to too much movement by the operator or patient Wait 15 seconds and repeat the temperature Repeat the temperature measurement as described in the section titled Taking the Temperature Steady battery symbol red indicator light insufficient battery power for a measurement Refer to page 23 Warranty Indication Meaning OPERATION OTHER SCREEN INDICATIONS 12 ...
Page 13: ...le Do not touch the sensor Cover with the hood and store in a dry place Pull the hood of the neoprene case back Grab the ARC InstaTemp on its sides and pull out of the case To insert the ARC InstaTemp into the neoprene carrying case To remove the ARC InstaTemp from the neoprene carrying case CARRYING STORAGE If accessory is included 1 1 2 3 2 13 ...
Page 14: ... be attached to any smooth vertical surface using its adhesive pad on the rear of the wall mount Because it is magnetic the wall mount can also be attached to any metal surface The internal magnet also keeps the ARC InstaTemp gently attached to the wall mount 14 ...
Page 15: ... drink In these instances wait 20 minutes before taking a temperature reading Do not apply any hot or cold compress cloth or gel based on the person s forehead prior to the measurement for at least 20 minutes Do not drop tap or shake the ARC InstaTemp thermometer It is a precision device and any damage may result in an inaccurate reading The temperature in the forehead area differs from the intern...
Page 16: ... thermometer to become damp or immersed in water or other liquids Do not touch the lens of the infrared sensor The sensor is the most important and sensitive part of the device Do not attempt to measure body temperature with the thermometer if a The thermometer has been exposed extreme conditions b It has been exposed to electric current or electromagnetic fields c It has been exposed to moisture ...
Page 17: ...the device touches or comes in contact with the person a Do not take a measurement for 5 minutes b Check the device lens and opening for contaminants c To clean the device please use a standard IPA wipe Do not touch the lens of the sensor It is the most delicate part of the ARC InstaTemp thermometer and must be protected from dirt and damage PRECAUTIONS CLEANING 17 ...
Page 18: ...InstaTemp in water or other liquids It is not water resistant Take care not to scratch the lens of the sensor the display or the housing Never use aggressive cleaning agents Clean the thermometer using an IPA wipe CLEANING 18 ...
Page 19: ...n a fire as batteries may explode when exposed to excessive heat When this product reaches its end of life take it to a collection point designated by local authorities Some collection points accept products for free The separate collection and recycling of your product at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human healt...
Page 20: ...structions can result in serious injury or damage to the device Caution consult section titled Understanding the Temperature Range Indicator System and Taking a Temperature Degree of protection against electrical shock there is no conductive connection to the person Type BF Protection DIRECTIVE 2012 19 EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electron...
Page 21: ...w 20 minutes for the device to acclimate to the operational environment Storage Transport Temperature Please store the device within the temperature range 45 to 90 F 7 32 C Measurement Accuracy Laboratory Error ASTM laboratory accuracy requirements in the display range 98 6 F to 102 2 F 37 0 C to 39 0 C for IR thermometers is 0 4 F 0 2 C within the operating temperature range of 59 F to 95 F 15 C ...
Page 22: ...isplay period is complete the ARC InstaTemp will automatically shutdown to conserve measurement lifetime Power Supply Contains 2 AAAA Alkaline Batteries internal non replaceable Battery Life Approx 7 500 measurements Thermometer Size 1 37ins x 0 55ins x 5 08ins 34 8mm x 14 0mm x 129 0mm Weight 1 94oz 55gm Electromagnetic Compatibility This device complies with the EN60601 1 2 standard for electrom...
Page 23: ... for questions regarding operation of the ARC InstaTemp thermometer contact ARC Devices Customer Support Department Monday Friday 9 00 AM to 4 00 PM ET at 1 561 282 6074 for general operational questions repair or replacement at no charge ARC Devices reserves the right to replace a defective product with the most comparable product currently available Should service be required during or after the...
Page 24: ... product without notice Contact ARC Devices PT 100174 CF1 Rev05 Manufactured and Distributed by ARC Devices USA Inc 1200 N Federal Hwy Ste 207 Boca Raton FL 33432 USA Phone 1 561 282 6074 info instatemp com www instatemp com EU Authorized Representative Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands 24 ...