60
1201 Utility Software
7.19
Setting to Factory Defaults
At some time it may be necessary to reset the Model 1201B/C to its original firmware configuration
when it left the factory. This is called “resetting to factory defaults” and requires disabling security.
Resetting the clock to factory defaults
clears memory
including any information that may cause
problems with its operation. To return the Model 1201B/C firmware configuration to factory
defaults, follow the instructions listed below. After resetting, you can use the Utility to save the
default configuration to file.
1. Disable security (to level 0) on the Model 1201B/C using the utility software.
2. Cycle power on the Model 1201B/C OFF, then ON.
3. Press the Setup key when you see the first message displayed on the LCD, and display message
should change to:
MODEL 1201X CLOCK
VERSION DDMMMYY
Then the display should change to read:
SET FACTORY DEFAULTS?
PRESS ENTER
4. Press the Enter key and the message should change to read:
ARE YOU SURE?
YES = UP NO = DOWN
5. Press the UP key to complete the reset to defaults. The display should indicate the following
messages.
LOADING DEFAULTS
DEFAULTS COMPLETE
6. The factory default settings should now be restored.
7. Reset security on the Model 1201B/C if required.