10.3 Command Set
93
0DT returns the current Daylight Saving / Summer Time Settings to the current COM port.
Response: (Mode: OFF, ON, or AUTO)
Mode:AUTO
C
START:02:00 Second SUN of MAR
C
STOP :02:00 First SUN of NOV
C
Set Daylight Saving/Summer Auto Start Time
Command:
2,w,x,y,zDT
Sets the date and time when Daylight Saving / Summer Time starts.
Where,
w = Month (0 through 11), with 0 = Jan, 1 = Feb, ... 11 = Dec.
x = WeekOfMonth (0 through 5), with 0 = First, 1 = Second, 2, = Third,
3 = Last, 4 = Second from Last, and 5 = Third from Last.
y = DayOfWeek (0 through 6), with 0 = Sun, 1 = Mon, ... , 6 = Sat.
z = Minutes after midnight z (0 through 1440).
Response:
C
Set Daylight Saving/Summer
Command:
3,w,x,y,zDT
Sets the date and time when Daylight Saving / Summer Time stops. Where,
w = Month (0 through 11), with 0 = Jan, 1 = Feb, ... 11 = Dec.
x = WeekOfMonth (0 through 5), with 0 = First, 1 = Second, 2, = Third,
3 = Last, 4 = Second from Last, and 5 = Third from Last.
y = DayOfWeek (0 through 6), with 0 = Sun, 1 = Mon, ... , 6 = Sat.
z = Minutes after midnight z (0 through 1440).
Response:
C
Local Offset Command
Command:
mLT
mLT sets the local offset in minutes from -720 to +720 (-12 to +12 hours), where m equals the
number of minutes, positive (East) or negative (West).
Response:
C
10.3.8
Front Panel Control Commands
Front Panel and Backlight Control
Command:
m,nFP
This command controls two actions; it enables or locks the keypad, and offers backlight control. m
= 0 enables the keypad, and m = 1 locks the keypad. n = 0 turns OFF the backlight, n = 1 turns