90
Startup and Basic Operation
Deviation Display
1 PPS: 0.00
µ
S
SIGMA: 0.00
µ
S
10.2.5
IRIG-B Time Data
IRIG-B time is immediately sent out, when the clock is powered ON, from any timing output
port configured for IRIG-B as indicated above. Time will not be accurate until the Unlocked LED
extinguishes.
10.3
Clock Status Display Mode
When first applying power to the clock, the display will indicate several startup messages, then
will revert to Clock Status mode condition called STARTUP. After a short time, while the GPS
receiver begins collecting data from the GPS, it will indicate either UNLOCKED (XX Min), NOT
STABILIZED, LOCKED–AUTO SURVEY, or LOCKED–POSITION HOLD. If they exist, faults
are indicated as follows:
Bit
Weight
Function
0
1
OCXO Not Installed (set to 1)
1
2
Stabilized (stabilized = 1)
2
4
Power Supply Error
3
8
IRIG BUS Fault (was Opt. 18)
4
16
Out of Lock
5
32
Time Error
6
64
VCXO Error
7
128
Receiver Failure
Table 10.1: Fault Conditions
For additional information on internal faults, please see Section 2.3.5, Section 8.1.3 and the
System Status command including Table 9.3 starting on page 73.
10.4
Time Display Modes – 1084B/C
After establishing GPS satellite synchronization, date and time information can be displayed on
the front panel by pressing the TIME key and scrolling through the four available displays. Press
this key to select the time display mode (UTC or Local) time data (Date/Time or Day of Year).
Summary of Contents for 1084A
Page 4: ...iv ...
Page 6: ...vi ...
Page 18: ...xviii LIST OF FIGURES ...
Page 24: ...4 Unpacking the Clock ...
Page 36: ...16 Connecting Inlet Power Input and Output Signals ...
Page 44: ...24 GPS Antenna and Cable Information ...
Page 114: ...94 Startup and Basic Operation ...
Page 123: ...B 4 Physical Dimensions 103 Figure B 1 Suggested Mounting of the AS0094500 Surge Arrester ...
Page 124: ...104 Using Surge Arresters ...
Page 134: ...114 Options List C 6 2 Option 06 Firmware Setup Figure C 3 Option 06 Firmware Setup ...
Page 142: ...122 Options List Figure C 5 Option 06 Output Jumper Settings ...
Page 158: ...138 Options List Figure C 13 Option 17 Board Layout and Jumper Locations ...
Page 163: ...C 13 Option 20A Four Fiber Optic Outputs 143 Figure C 14 Option 20A Jumper Locations ...
Page 170: ...150 Options List Figure C 16 Option 23 Internal Jumper Setup ...
Page 172: ...152 Options List Figure C 17 Option 27 Jumper Locations ...
Page 190: ...170 Options List Figure C 20 Option 29 Connector Signal Locations ...
Page 246: ...226 Options List ...