23
9
TECHNICAL DATA
Overall capacity – Litre (quarts)
60 (63)
Type
1080050
Category
1
Annual Energy Consumption (KWh/annum)
100
Climate Class
N,T
Energy Efficiency Index (EEI)
A+
Connection voltage (except North America)
12/24 V DC and 100-240 V AC
Connection voltage North America
12/24 V DC and 120V AC ~ 60Hz
Rated current
-
12V DC
6.8 A
-
24V DC
3.4 A
-
100-240 VAC
1.0 – 0.5 A
-
120 VAC
1.0 A
Cooling Capacity
+ 10 °C to –18 °C (+50 °F to 0 °F)
Ambient Temperature
+16°C to +43°C (+70 °F to +109°F)
Weight – Nett - Kg (lb)
32 (70)
Noise (dbA)
50
Refrigerant - R134a – g (oz)
58 (2.0)
External Dimensions – mm (in) – Figure 17a
-
H1
435 (17.3)
-
W1
490 (19.3)
-
D1
820 (32.3)
Internal Dimensions – mm (in) – Figure 17b
-
H2
332 (13.1)
-
H3
144 (5.7)
-
W2
355 (14.0)
-
D2
477 (18.8)
-
D3
633 (24.9)
Note: The maximum cooling capacity is 50°C (122°F) below ambient
temperature. If the ambient temperature is above 32° (90°F) the minimum
temperature cannot be achieved.
Figure 17a
Figure 17b
This device is CFC-free. The coolant circuit contains R134a. Removal or recharge of
refrigerant should only be done by an authorised refrigeration mechanic.