NOX System
User manual
V1.91 - January 2015
6 / 44
Door opener with a key pad:
Insert a valid user code
Confirm with enter key “E”
→
the door opener is activated
Arm-/Disarm with the key pad:
Insert a valid user code
Confirm with enter key “E”
To arm press the function key with the closed latch „
“
To disarm press the function key with the open latch „
“
Accessing the main menu
To access the main menu, a correct user code is required. The main menu might differ from
user to user as the user rights differ.
Notice
: If 5 invalid user codes are entered within 3 minutes (adjustable), the control panel
locks itself and will not accept further codes (invalid or valid) for 3 minutes.
Additional error codes will cause the system to block for a longer time (the system can be set
up to trigger a tamper).
To unlock the control panel, it’s necessary to make an alarm or wait until the unlocking time
has been reached. This time will be shown on the control panel by a time-counter.
If 36 invalid codes are entered within 12 hours, the control panel will lock for 12 hours.
All time settings are adjustable!