28
IMPLEMENT SETTINGS
11.9.3
Tank profile calibration
The calibration of the tank profile is ONLY possible if a flowmeter is installed on the system
Before starting the procedure carry out the following operations:
1
Make sure that the main control is set to OFF
2
Fill the tank with clean water WITHOUT ADDING CHEMICAL SUBSTANCES. The tank must be full.
Visually check the reached level.
3
Set the output to the maximum value by acting on the control valve control (nearly 7 s).
THE FLOWRATE MUST BE WITHIN THE FLOWMETER OPERATING RANGE.
4
Start the procedure by pressing
Start
.
5
Start the spraying system: open, in succession, all section valves and the main control (
ON
).
The display will show in real time the quantity of sprayed water and the calibration status.
6
When the tank is empty press
Confirmation
to end the procedure:
the value read by the level sensor must be lower than 5,0 mA and at least 10 liters must have been sprayed.