TECHNICAL DATA

Power supply voltage

9 ÷ 16 Vdc

Operating temperature

-20°C / +70°C

-4 °F ÷ +158 °F

Storage temperature

-40 °C ÷ +85 °C

-40 °F ÷ +185 °F

Protection against polarity inversion

Protection against short-circuit

Protection rating

IP65

12 

END-OF-LIFE DISPOSAL

Dispose of the system in compliance with the established legislation in the country of use.

13 

WARRANTY TERMS

1.  ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery 

note).

 

The components of the apparatus, that in the unappealable opinion of ARAG are faulty due to an original defect in the material or 

production process, will be repaired or replaced free of charge at the nearest Assistance Center operating at the moment the request for 

intervention is made. The following costs are excluded:

-  disassembly and reassembly of the apparatus from the original system;

-  transport of the apparatus to the Assistance Center.

2.  The following are not covered by the guarantee:

-  damage caused by transport (scratches, dents and similar);

-  damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the electrical system, or to 

alterations resulting from environmental, climatic or other conditions;

-  damage due to the use of unsuitable chemical products, for spraying, watering, weedkilling or any other crop treatment, that may damage 

the apparatus;

-  malfunctioning caused by negligence, mishandling, lack of know-how, repairs or modifications carried out by unauthorized personnel;

-  incorrect installation and regulation;

-  damage or malfunction caused by the lack of ordinary maintenance, such as cleaning of filters, nozzles, etc.;

-  anything that can be considered to be normal wear and tear;

3.  Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance Center.

 

No guarantee conditions will be recognized for those units or components that have not been previously washed and cleaned to remove 

residue of the products used;

4.  Repairs carried out under guarantee are guaranteed for one year (360 days) from the replacement or repair date.

5.  ARAG will not recognize any further expressed or intended guarantees, apart from those listed here.

 

No representative or retailer is authorized to take on any other responsibility relative to ARAG products.

 

The period of the guarantees recognized by law, including the commercial guarantees and allowances for special purposes are limited, in 

length of time, to the validities given here. 

 

In no case will ARAG recognize loss of profits, either direct, indirect, special or subsequent to any damage.

6.  The parts replaced under guarantee remain the property of ARAG.

7.  All safety information present in the sales documents regarding limits in use, performance and product characteristics must be transferred 

to the end user as a responsibility of the purchaser.

8.  Any controversy must be presented to the Reggio Emilia Law Court.

14 

DECLARATION OF CONFORMITY

The declaration of conformity is available at the website www.aragnet.com, in the relevant section.

Summary of Contents for EXPLORER

Page 1: ...INSTALLATION USE AND MAINTENANCE 46701802 MULTI FUNCTION JOYSTICK Software rel 2 3 X ...

Page 2: ...ge content 3 5 Overall dimensions and fastening 4 6 Wiring connections 5 6 1 General precautions for a correct harness position 5 6 2 Wiring harness connection 5 7 Using the keys 6 7 1 Quick function list consultation long press P2 6 8 Switching on 7 9 Indications LEDs and vibrations ISOBUS MODE 7 10 Object pool 8 10 1 OBJECT POOL loading 8 10 2 ISOBUS 8 10 3 Functions assignment 9 10 3 1 Automati...

Page 3: ...installed together with other brands components get damaged because of what stated above no direct or indirect warranty will be provided 1 RISKS AND PROTECTIONS BEFORE ASSEMBLY All installation works must be done with battery disconnected using suitable tools and any individual protection equipment deemed necessary Use ONLY clean water for treatment tests and simulations using chemicals during sim...

Page 4: ...4 5 OVERALL DIMENSIONS AND FASTENING Fig 2 CLAMP FASTENING 1 1 Ø 27 mm 2 2 3 3 Fig 3 THREAD FASTENING M10 M10 1 1 4 4 3 3 5 5 2 2 Fig 4 ...

Page 5: ...d or bending them the contacts may be damaged and device operation may be compromised Use ONLY the cables and accessories indicated in the catalog having technical features suitable for the use to be made of them 6 2 Wiring harness connection CAUTION A net and ISOBUS models of the joystick cannot be replaced with each other They use the same connector but are equipped with two different software p...

Page 6: ...other pages Fig 9 FUNCTIONS Main page P0 FUNCTIONS PAGE 1a FUNCTIONS PAGE 1b FUNCTIONS PAGE 2 Fig 9 7 1 Quick function list consultation long press P2 Allows viewing the page for assigning functions to the keys of the EXPLORER joystick Press and hold the P2 button to access the assignment summary page directly This page is read only ESC FUNCTION LIST READ ONLY F u n c t i o n s a s s i g n m e n t...

Page 7: ...ibration LED No LED STATUS VIBRATION L1 PAGES 1 1 bis L1 steady on page 1 ONLINE 1 vibration 1 pause regular blinking page 1 bis ONLINE 1 vibration 1 pause off Main page ONLINE none off page 2 ONLINE 2 vibrations 1 pause L2 ALARMS INDICATION LED L2 off Object Pool correctly loaded correct ISOBUS operation none 1 periodic blink initialization none 2 periodic blinks Object Pool loading in progress n...

Page 8: ... 2 ISOBUS Delete OP 1 I S O B U S a d d r e s s I S O B U S n a m e I S O B U S D e l e t e O P C h a n g e V T E C U V T Fig 13 2 C o n f i r m C o n f i r m o b j e c t d e l e t i o n Fig 14 Use this function ONLY when some components of the Object Pool have not been loaded properly after deletion the Virtual Terminal reloads the entire application 1 Press to delete the Object Pool 2 Confirm wi...

Page 9: ... in the Settings menu choose the Single option Fig 18 E x p l o r e r J o y s t i c k I S O B U S F u n c t i o n s a s s i g n m e n t T e s t k e y s V e r s i o n s R e g i s t r a t i o n S e t t i n g s Fig 17 Single R e s e t t o A r a g f a c t o r y d e f a u l t s Keys configuration S e t t i n g s Fig 18 F u n c t i o n s a s s i g n m e n t Un mapped Un mapped Fig 19 Now it is possible ...

Page 10: ...t A Boom tilt C Var geom R A Var geom R C Seq 1 LH Seq 1 RH Main valve switch key Seq 2 LH Seq 2 RH PAGE 1a Arm no 2 L A Arm no 2 L C Arm no 1 L A Arm no 1 L C Arm no 1 R A Arm no 1 R C Arm no 2 R A Arm no 2 R C Boom lock A Boom lock C Main valve switch key Un mapped PAGE 1b Drawbar Steering axle AUTO MAN switch Height A Height C Boom tilt A Boom tilt C Boom leveling AUTO MAN switch Boom lock A Bo...

Page 11: ...elow is useful to manually assign the functions to the joystick keys in Single mode Main page P0 P0 P0 MAIN P0 P0 P0 P0 P0 P0 P0 P0 P0 P0 PAGE 1a PAGE 1b P1a P1a MAIN P1a P1a P1a P1a P1a P1a P1a P1a P1a P1a P1b P1b MAIN P1b P1b P1b P1b P1b P1b P1b P1b P1b P1b PAGE 2 P2 P2 MAIN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 ...

Page 12: ...ow is useful to manually assign the functions to the joystick keys in Dual mode Main page P0 P0 MAIN P0 P0 P0 P0 P0 PAGE 1a PAGE 1b P1a MAIN P1a P1a P1a P1a P1a P1b MAIN P1b P1b P1b P1b P1b PAGE 2 P2 MAIN P2 P2 P2 P2 P2 ...

Page 13: ...ation is correct the Virtual Terminal display shows a tick sign 10 5 Versions V e r s i o n s A p p l i c a t i o n H a r d w a r e r e v i s i o n S e r i a l n u m b e r I S O B U S s t a c k B S P R T O S Fig 28 It displays the versions of the currently used system CONTINUES ...

Page 14: ...cates that registration is correct 10 7 Settings D u a l R e s e t t o A r a g f a c t o r y d e f a u l t s K e y s c o n f i g u r a t i o n S e t t i n g s Fig 30 Keys configuration Allows selecting the type Single or Dual used to assign functions to the Joystick keys The two modes are described in paragraph 10 3 2 Reset to Arag factory defaults Allows restoring the device to factory default se...

Page 15: ...ce mishandling lack of know how repairs or modifications carried out by unauthorized personnel incorrect installation and regulation damage or malfunction caused by the lack of ordinary maintenance such as cleaning of filters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the organizational nee...

Page 16: ...ladio 5 A Tel 39 0522 622011 Fax 39 0522 628944 http www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time Always refer to the Internet address www aragnet com ...