82
17.3
Error messages
MESSAGE ON DISPLAY
CAUSE
REMEDY
Move forward! The machine is stopped
Main control ON with machine stopped
• Start the machine.
• Disable main control (OFF)
Enable pump! No flowrate.
Main control ON but flowrate at zero
• Start the pump and move the machine.
Stop spraying! Pump fault.
Output pump faulty
• Check pump operation
Automatic adjustment locked!
Pressure does not reach set value
• Increase driving speed
Limit was not set correctly
• Check set limit
Accelerate! High flowrate.
The flowrate exceeds the value required for
output
• Increase driving speed
• Check that the setup of the menu
Implement settings
(number of covered rows, flowmeter, etc.)
has been set correctly
Slow down! Insufficient flowrate.
The rate does not reach the value required for
output
• Decrease driving speed
• Make sure that flowmeter parameters are set correctly
Accelerate! Insufficient pressure.
The pressure does not reach the minimum value
for the nozzle in use
• Increase driving speed
• Adjust the operating pressure so as to respect the previously
set limits for nozzles in use.
• Check minimum pressure setting for nozzle in use
Slow down! High pressure.
The pressure exceeds the maximum level
allowed for the nozzle being used
• Decrease driving speed
• Adjust the operating pressure so as to respect the previously
set limits for nozzles in use.
• Check maximum pressure setting for nozzles in use
Maximum tank level reached!
Tank level has reached the maximum set value
• Stop tank filling phase
Minimum tank level reached!
Tank level is lower than the set reserve value
• Fill the tank (par. 15.1)
Minimum value was not set correctly
• Check set reserve value
Invalid signal of the pressure sensor!
The signal coming from the pressure sensor is
outside the permitted limits
• Check the status of connection cables (and connectors) and
sensor (ref. installation manual)
Tank level sensor signal invalid!
The signal coming from level sensor is outside
the permitted limits
• Check the status of connection cables (and connectors) and
sensor (ref. installation manual)
Flowmeter out of range!
Flowrate out of the limits allowed by flowmeter
• Modify working conditions to suit flowmeter limits (speed,
pressure, etc.)
• Make sure that flowmeter parameters are set correctly
RPM value above maximum set limit.
Excessive rotation speed
Reduce rotation speed
RPM value lower than minimum set limit.
Insufficient rotation speed
• Increase rotation speed
Increase rotation speed!
RPM does not reach the minimum value
• Increase the rotation speed of the moving part
• Check the constant set for the rev counter
Reduce rotation speed!
RPM exceeds the maximum set value
• Decrease the rotation speed of the moving part
• Check the constant set for the rev counter
Job origin too far away!
The current position is too far away from the job
• Redefine the job origin
GPS receiver not connected!
Wrong connection of receiver cable to monitor
• Check connection to receiver
(ref. installation manual)
The receiver connection cable is damaged
• Replace the cable
The receiver is damaged
• Replace the receiver
GPS receiver gives no valid position data.
The receiver is establishing a connection to the
satellites
• Wait for connection
GPS receiver version not supported
The software version is not compatible with the
monitor software
• Update the GPS receiver
GPS receiver waiting for valid position
data
The receiver is indoor
• Move the machine outdoor to improve satellite reception
Insufficient GPS quality
The position and number of satellites do not
allow a suitable driving precision
• Wait for signal strength to improve
Internal IBX unit error!
No communication between monitor and internal
IBX
• Contact technical service
External battery supply missing!
No voltage from supply source
• Check the supply source
Battery voltage of the tractor out of
device working range.
The supply source does not provide voltage
within the expected range (9÷16 V)
• Check the supply source
Job extension is getting closer to memory
admitted limit.
The overall saved job memory exceeds 98% of
internal memory
• Delete some job data