12.2
Data and settings > Working parameters
Set the farming machine job limits.
1
2
Fig. 82
SPEED
1
To configure the items on this menu, you must enable the speed limit.
Set the minimum working speed: The IBX100 Sprayer closes the main valve when the tractor speed is
lower than the set value.
CHANGE TARGET RATE
2
Set the target rate mode and increment value.
ENABLED:
percentage increment
DISABLED:
rate increment in l/ha
The target rate change is carried out with the job function described in
par.
4
3
Fig. 83
FLOWRATE CORRECTION FACTOR
3
When using a paddle flowmeter and the sprayed fluid has a different viscosity than that of water, the
VT could display wrong measurements; to correct them change the flowrate correction factor:
• if at the end of the spraying the tank still contains fluid, reduce the factor;
• if the fluid finishes before the job has ended, increase the factor.
Flowmeters of the ORION series (code 462xxx) are not affected by the viscosity difference of
the fluids: set the factor to 1.00.
PRODUCT DENSITY
4
If the sprayed fluid is lighter than water, the device may indicate wrong measurements; to correct
this measurement, edit the sprayed liquid weight, referred to 1 liter of product.
A tank level sensor
must be installed.
6
5
8
7
9
Fig. 84
REGULATION SETTINGS
5
Displays the type of selected control valve.
6
Checks the power applied by the selected valve to regulate the system flow.
-
It reduces aggressiveness.
+
It increases aggressiveness.
The ideal calibration is achieved when the application rate remains constant even with minor variations
in driving speed.
PRESSURE REGULATION CLOSE
7
Function of the control valve during closing.
ENABLED:
The system tries to reach the set pressure acting on the control valve (AUTO mode
enabled with main valve closed) ONLY for the time entered (
9
), after which the system does not
intervene on the valve anymore.
DISABLED
8
Set the pressure value to be reached when the sections are closed.
9
Maximum time needed by the control valve to bring the boom to the set pressure.
This function can be activated only if the pressure sensor is set in the basic settings and installed on
the implement.