30
IMPLEMENT SETTINGS
Quits without confirming the
changes
Saves the changes
Cancel
Exits
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to main screen
Saves the changes to current
page
11.9.5
Home > data and settings > implement settings > Device calibration > Load tank profile
Allows importing a tank profile calibration file present in an external memory connected to the Virtual Terminal.
1
3
4
5
2
2A
2B
Fig. 57
Press
Load tank profile
to enter the File server management menu from which you
can select the folder from which to import the Tank profile file.
The button is visible only if the VT supports the ISOBUS File server
feature.
1
Current folder path.
2
List of files contained within the current folder.
In order to be loaded, the backup file must have the extension .pro and must be inside
the folder MCMC0258. This folder refers to ARAG because 0258 is the code that
identifies ARAG as the ISOBUS component manufacturer.
2A - 2B
Buttons to select the file to load.
3
BACK. Goes back to the previous folder.
4
HOME. Returns directly to the home folder (MCMC0258) - This function may not be
available in all Virtual Terminals.
5
COPY. Confirms the copy of the selected tank profile file to the internal memory of
IBX100.
Summary of Contents for 4679004