ARAG 46212A01313 Installation, Use And Maintenance Manual Download Page 1

46212AXXXXX

46222AXXXXX

ELECTROMAGNETIC FLOWMETER

INSTALLATION, USE AND MAINTENANCE

Summary of Contents for 46212A01313

Page 1: ...46212AXXXXX 46222AXXXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE...

Page 2: ...Operation mode 7 3 6 UNIT Unit of measure 7 3 7 VAL Valve operation time 7 4 USE 8 4 1 Mode 0 Mode 2 Use 8 4 2 Mode 1 Operation 9 5 MAINTENANCE 10 5 1 Troubleshooting 10 5 2 Technical data 11 6 GUARAN...

Page 3: ...monized with 2014 30 UE Directive The flowmeter must not be used to measure the passage of hydrocarbons flammable explosive or toxic liquids The flowmeter is not suitable for contact with liquids for...

Page 4: ...be positioned upwards Comply with the correct fluid inlet outlet direction as indicated by the arrow printed on the flowmeter body Fig 4 Use inlet and outlet pipes of the same diameter as the internal...

Page 5: ...GND Red 2 12 VDC Green 3 Signal square wave Yellow 4 Pump check 2 4 Hydraulic connections For connection to the system use appropriate fittings Ref ARAG General catalogue Avoid bends and constrictions...

Page 6: ...o modify the value keep the keys pressed simultaneously until the SET screen appears 3 Set the flow meter constant using the TOT key to increase it and the RESET key to decrease it keep the keys press...

Page 7: ...U Europa l l min predefined setting US USA Gal Gpm 1 2 3 4 1 Press in sequence to display the type of current unit of measure the value alternates with the message UNIT 2 To modify the value keep the...

Page 8: ...ts the flowmeter could give incorrect data and therefore lead the operator or the automatic system to make errors ARAG cannot be held responsible for damage caused to persons animals or things by inco...

Page 9: ...T screen appears If the instantaneous quantity is displayed STRT screen does not appear in this case press TOT key to display it 2 To resume loading press RESET key again 3 To complete loading before...

Page 10: ...or abrasive objects for cleaning the duct Do not use solvents or petrol for cleaning the external parts of the device 5 1 Troubleshooting FAULT CAUSE REMEDY The flowmeter does not read any value No p...

Page 11: ...0 46212A03333 0 5 10 0 13 2 6 40 580 0 3 4 G 3 4 5 6000 22710 46212A11313 1 20 0 3 5 20 290 0 3 4 G 3 4 7 3000 11355 46212A13333 1 20 0 3 5 40 580 0 3 4 G 3 4 7 3000 11355 46212A21313 2 5 50 0 6 13 20...

Page 12: ...nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the organisational needs of the Assistance Centr...

Page 13: ...Note 13...

Page 14: ...ilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained...

Reviews: