Shielding collar or shield clamp for [ST1]
For EMC-compliant connection of [ST1], a shielding collar, shield clamp, or similar that is suitable
for the respective application is required. This is not included in the scope of delivery of the mating
connector.
Relevant links for [ST1]
Link to the product catalog on the TE homepage
Link to the assembly manual of the mating connector on the TE homepage
Link to the operating manual of the crimping pliers on the TE homepage
3.14.4
Cables for [ST2] and [ST3]
Specification of the cables for the crimp contacts for [ST2] and [ST3]
In addition to the general requirements for the cables, it is also important to note the following:
•
The number of conductors per cable depends on the number of occupied pins.
•
The size of the conductors depends on the size of the respective crimp contacts.
•
The crimp contacts are supplied with the mating connector. The cable is not included in the
scope of delivery.
Description
Value
Conductor cross-section
0.14 – 1.0 mm² Cu / 18 – 26 AWG Cu
Maximum conductor diameter
n/a
Maximum current load per crimp contact
7
A
Table 41: Specification of the cable for the crimp contacts for [ST2] and [ST3]
Relevant links for [ST2] and [ST3]
Link to the product catalog on the Intercontec homepage
Link to the assembly manual for series 623 on the Intercontec homepage
3.14.5
Cable for [ST4]
[ST4] optional for VECTOPOWER VP5000-DC/DC60 only
Specification of the cables for the crimp contacts for [ST4]
In addition to the general requirements for the cables, it is also important to note the following:
•
The cable for [ST4] must be voltage-proof up to at least 800 V DC.