VP5000-DC/DC60, VP5000-DC/DC200-HL
Product description
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
44 / 173
Connection thread of
EMC cable gland
Sealing area without
inlet max./min.
∅
mm
Sealing area with inlet
max./min.
∅
mm
Shield diameter
max./min.
∅
mm
M12x1.5
8.0 - 5.0
- / -
5.0 - 3.0
M16x1.5
11.0 - 7.0
- / -
9.0 - 5.0
M20x1.5
14.0 - 9.0
- / -
12.0 - 7.0
M25x1.5
20.0 - 16.0
16.0 - 11.0
16.0 - 10.0
M32x1.5
25.0 - 20.0
20.0 - 15.0
20.0 - 13.0
M40x1.5
32.0 - 26.0
26.0 - 20.0
28.0 - 20.0
M50x1.5
42.0 - 35.0
35.0 - 31.0
37.0 - 28.0
M63x1.5
54.0 - 46.0
46.0 - 41.0
46.0 - 37.0
M75x1.5
65.0 - 58.0
58.0 - 54.0
58.0 - 46.0
M85x2.0
77.0 - 70.0
70.0 - 65.0
65.0 - 58.0
Table 23: Data on EMC cable gland from Pflitsch, blueglobe TRI type
Logical connections
3.7
The design and pin assignment of the logical connections are given in the following tables.
Depending on the design of the respective VECTOPOWER, not all logical connections and pins are
available for all devices.