![AR 10051217 Operating And Service Manual Download Page 64](http://html1.mh-extra.com/html/ar/10051217/10051217_operating-and-service-manual_2962298064.webp)
Model 2000S1G2z8
40
Rev A
2.13.1
Power On/Off
This command controls the power state. No other command will be accepted until the
POWER:ON
command
has been issued.
It is good practice to wait a minimum of two (2) seconds before polling the status after issuing the
POWER:ON
command.
Syntax:
POWER:<ON|OFF>
Query
No (see Amplifier State Query command)
Example
To turn the power on, send the following command:
POWER:ON<LF>
Default Value:
OFF
2.13.2
RF On / Off
This command enables the RF output of the amplifier if already powered on and no faults are present.
Syntax:
RF:<ON|OFF>
Query:
No (see the Amplifier State Query command)
Example
To enable the RF Output, send the following command:
RF:ON<LF>
Default Value:
OFF
2.13.3
RF Gain Adjust
This command sets the RF Gain of the amplifier, in percent.
Syntax:
LEVEL:GAIN<gain value>
<gain value>:
Specifies the RF gain in % from
0
(minimum) to
100
(maximum)
Query:
No (see the Machine State query command)
Example
To set the RF Gain to maximum, send the following command:
LEVEL:GAIN100<LF>
Default Value:
0%
2.13.4
RF Gain Query
This command queries the RF Gain setting.
Query:
RFG?
Response Format:
RFG=<space><rf gain><LF>
<rf gain>:
The current RF Gain, in percent (0000 to 0100, padded with zeros to always
be 4 digits wide).
Example:
To query the RF Gain, send the following command:
RFG?<LF>
Response:
RFG=<space>0075<LF>
(75% Gain)
Summary of Contents for 10051217
Page 2: ......
Page 4: ......
Page 6: ......
Page 18: ...Model 2000S1G2z8 iv...
Page 22: ...Model 2000S1G2z8 4 Rev A...
Page 85: ...Model 2000S1G2z8 Rev A 61 Figure 4 2 Typical Response at 0 dBm Input...
Page 86: ...Model 2000S1G2z8 62 Rev A...
Page 88: ...Model 2000S1G2z8 64 Rev A...
Page 90: ......