2.2.1.5
Menu Map
Figure 2-3 shows the menu map for the 60/40S1G18B Multi-Band Amplifier. The screens depicted are only
example screens. The actual values and settings will be different on the actual amplifier depending on user
settings and operating conditions.
Figure 2-3. Menu Map
2.3 LOCAL OPERATION
2.3.1
Power-up Sequence
1.
Connect the input signal to the unit’s RF INPUT connector. The input signal level should be 0dBm
maximum.
2.
Connect the load to the unit’s RF OUTPUT connector.
3.
Check to see that the MAIN POWER switch on the unit’s rear panel is set to the 1 (on) position.
4.
Press the POWER switch: the front panel vacuum fluorescent display (VFD) should read
POWER ON
,
when power is applied.
NOTE:
The amplifier changes state each time the POWER switch is depressed—if the unit is on when
the POWER switch is depressed, it will turn off; if the unit is off when the POWER switch is
depressed, it will turn on.
5.
Using the touch screen, select the HI BAND or LO BAND as desired.
6.
Using the touch screen, turn amplifier on.
7.
Adjust the amplifier’s gain by rotating the GAIN knob.
8.
In the event of a fault, press the FAULT/RESET switch; if the fault does not clear, refer to subsection 4.3
Troubleshooting
of this manual.