Model 150/150AW1000
20
Rev C
2.4.6.15
Faults
Query to find the faults that have occurred with the amplifier.
Syntax:
FSTA?
Parameters:
None
Response Format:
FSTA=<space>00xx
Where:
xx
=
00
to
17 (Hexadecimal)
xx
Dec
Description
00
00
No Fault
02
02
Interlock
03
03
PS1
04
04
PS2
05
05
PS3
06
06
Thermal A2
07
07
Thermal A7
08
08
Thermal A6
09
09
Thermal A4
0A
10
PS2 Thermal
0B
11
PS3 Thermal
14
20
Amp A2
15
21
Amp A7
16
22
Amp A6
17
23
Amp A4
Example:
To find out what faults have occurred, send the following query.
FSTA?<LF>
Response:
FSTA= 0002<LF>
(Interlock Fault)