Model 3000W1000B
Rev A
37
4.3.6
Fault Troubleshooting Guide
Driver
Fault
Type of Fault
Possible Reasons
485 driver
Communication
Disconnected or faulty W23 or W22 CAT5 cable.
Therm driver (A2, A4-A6)
Thermal
Driver fan blocked or clogged.
Amp Fault (A2, A4-A6)
Under Current,
Over-Current
Driver FET is damaged and drawing no current, Gate voltage is
being pulled down. Driver FET had been over driven. Usually
resettable and cured by backing off input drive.
PS1, PS2
Power Supply
PS1 or PS2 has failed
ALC
Leveling
ALC circuit is not working and allowing the RF power to exceed a
preset limit
500 Watt Power Amplifier
B1-B6
Fault
Type of Fault
Possible Reasons
Therm (B1-B3) (A7-A14)
Thermal
Amp Fault (B1-B3) (A7-
A14)
Under Current
Over-Current
Final module FET is damaged and drawing no current, insufficient
gate voltage to FET. Final module FET had been over driven.
Usually resettable and cured by reducing input drive.
PS1 Final (B1-B3)
Power Supply
PS1 has failed inside MPA listed
PS2 Final (B1-B3)
Power Supply
PS2 has failed inside MPA listed