Model 1000S1G6C
28
Rev A
2.8.2
Switch Breakout Board (A37)
2.8.2.1
Connector J9
Notes
Indicate a range representing a NO ACTION STATE (i.e. +1.2 Vdc << +2.3 Vdc)
Once activated, inputs are checked for all following control states
Guaranteed operation between 0.0 Vdc and +3.3Vdc (damage occurs outside this range)
Control
Line
Input
Control States
Defined in section 4
Fault?
= Yes
General Description
Add fault description in section 2.9
Add non-fault description in section 2.9.1
Pwr OFF
RF OFF
Pwr ON
RF OFF
Pwr ON
RF ON
J9 – 1
Analog
J9 – 2
Analog
J9 – 3
Analog
J9 – 4
Analog
2.8.2.2
Connector J8
Notes
These outputs are not state-driven (always on) and can be set to a fixed value in the range of 0.0 Vdc to 4.8 Vdc
Line
Output
Value
J8 – 1
Analog
J8 – 2
Ground
J8 – 3
Analog
J8 – 4
Ground