AquaTools AT8550 Owner'S Manual Download Page 1

Above Ground Cartridge Filters

Models AT8550 and AT8575

O   W   N   E   R ’   S

M   A   N   U   A   L

INSTALLATION, OPERATION & PARTS

AquaTools

293 Wright Street, Delavan, WI 53115

North America: 800-752-0183, FAX 800-582-2217 
International: 262-728-5551, FAX: 262-728-4461, TELEX: ITT 4970245

© 2000, Printed in U.S.A.

AT530 

(10/31/01)

This manual should be furnished to
the end user of this filter; its use will
reduce service calls and chance of 
injury and will lengthen filter life.

PUSH

PUSH

INLET

INLET

Summary of Contents for AT8550

Page 1: ...eet Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 262 728 5551 FAX 262 728 4461 TELEX ITT 4970245 2000 Printed in U S A AT530 10 31 01 This manual should be furnished to t...

Page 2: ...NPT Posi Ring TM Air Release Valve PressureGauge Behind Safety Latch Minimum Service Height Pressure Gauge Not Factory Installed 3648 0200 IN OUT SPECIFICATIONS FIGURE 1 Dimensions in inches mm Table...

Page 3: ...ol and operating filter A typical pool installation will require approximately one week to obtain and maintain the sparkle that your filter is capable of giving you Maximum pressure is 30 PSI 207 kPa...

Page 4: ...and all sealing surfaces Relubricate the O ring if necessary NOTICE Lubricate the O ring only with silicone grease as other lubricants may cause the ring to swell DO NOT lubricate the Posi Ring or the...

Page 5: ...move the drain cap and flush all foreign material from the inside of the tank before removing the filter cartridge 2 Allow the tank to drain 3 Lift out the cartridge and hose it down thoroughly Spray...

Page 6: ...xcessive air in filter Vent air from tank and check for pump suction pipe leaks Clean air bleed filter in cartridge assembly with a hose and soft flow nozzle D Pool water contains iron Consult your po...

Page 7: ...5 Tank lid assembly includes Key No 6 1 25200 0103S 25200 0103S 6 Tank lid O ring with silicone lube 1 25200 0011S 25200 0011S 7 Filter cartridge 1 25200 0150S 25200 0175S 8 Safety catch 1 25200 0007...

Page 8: ...t to negligence misappli cation improper installation or maintenance or other cir cumstances which are not in AquaTools direct control Full warranty coverage is in effect for one year after instal lat...