The lamps are packaged in a protective tube to help eliminate damage during shipping.
1)  remove the lamps from their protective tubes.

2)  T5 ho lamps use a mini bi-pin connection to make contact with the fixture's sockets.  To install, 

insert both ends of the lamp into sockets and rotate 90 degrees. The min bi pin connections 
should now be horizontal in the socket.

          

 

3)  install lamps in the following sequence:

•  1st  10,000 K Lamp, in sockets closest to front of fixture
•  2nd 420/460 Lamp, in second sockets from front of fixture
•  3rd 10,000 K Lamp, in third sockets from front of fixture
•  4th 420/460 Lamp, in sockets closest to back of fixture

The Timer will control the lamps in the above arrangement. any change in the sequence of lamps 
will change the Timer’s ability to control the lamps as designed. 

LaMPs

PaCkaging

3)  your new fixture includes a plastic film on the lens cover to protect it during shipping. peel the 

protective film off both sides of the acrylic lens cover.

Page 8

Page 7

Page 9

NOTE:

 do noT replace the 

acrylic lens cover until the 
aquarium frame Mounts 
have been attached.

Summary of Contents for 420035

Page 1: ...ight Fixtures For Models 420049 Compact Fluorescent 24IN 420050 Compact Fluorescent 36IN 420051 Compact Fluorescent 48IN 420052 Compact Fluorescent 72IN 420035 T5 HO 24IN 420151 T5 HO 30IN 420036 T5 H...

Page 2: ...e for use with your marine and freshwater aquarium We know you value quality and innovation and will be pleased with this product s performance We encourage you to take a few minutes to become familia...

Page 3: ...sing 13 Lens Cover 13 t5 ho fluorescent Models 420035 420036 420151 420037 420038 Parts Specifications 14 Parts Diagram 14 Product Specifications 15 Installation 16 Packaging 16 Lamps 17 Aquarium Fram...

Page 4: ...ng the cord and coming in con tact with the receptacle If the plug or receptacle does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance Then unp...

Page 5: ...e the adaptor illustrated in A may be used to connect this plug to a two pole receptacle as shown in A if a grounded outlet is not available A temporary adaptor should only be used until a grounded ou...

Page 6: ...6 compact fluorescent parts Specs Parts Diagram...

Page 7: ...e 3 Model Numbers 420049 420050 420051 420052 Rated Voltage 120 Volt AC Rated Cycle 60Hz Power Factor 0 95 0 95 0 95 0 95 Power Cord Length 2 meters 3 meters Dimensions without Frame Mounts L x W x H...

Page 8: ...emoved prior to operation Place the light fixture upside down on a surface that will not mar or scratch the finish packaging TIP Use a large towel under the fixture while removing the shipping materia...

Page 9: ...ached Page 8 Page 7 Page 9 Page 8 Page 7 Page 9 5 Acrylic scratches easily and your new fixture includes a plastic film on the Lens Cover to protect it during shipping Peel the protective film off bot...

Page 10: ...de into the channels on the sides of the light fixture Aquarium Frame Mounts compact fluorescent installation Page 8 Page 9 Page 8 Page 9 Page 8 Page 9 Page 8 Page 7 Page 9 P a g e 8 P a g e 7 P a g e...

Page 11: ...I The display will illuminate when power is supplied The Digital Timer controls three Zones in the Marine Light Fixture 10 000 K Lamps 420 460 Lamps and Lunar LED s Each of these Zones can be programm...

Page 12: ...your local store or supplier for a recommendation for frequency of replacement To remove and replace Lamps follow the Installation procedure for Packaging on page 9 The instruc tions will show how to...

Page 13: ...Wipe the Acrylic Lens Cover with fresh water or an acrylic cleaner to maintain peak light transmis sion If the Lens Cover is allowed to become dirty it will reduce the amount of light that enters the...

Page 14: ...14 t5 ho fluorescent parts Specs Parts Diagram...

Page 15: ...Maintenance Guide 3 Model Numbers 420035 420151 420036 420037 420038 Rated Voltage 120 Volt AC Rated Cycle 60Hz Power Factor 0 55 0 55 0 55 0 59 0 55 Power Cord Length 2 meters 3 meters Dimensions wit...

Page 16: ...to be removed prior to operation Place the light fixture upside down on a surface that will not mar or scratch the finish Packaging TIP Use a large towel under the fixture while removing the shipping...

Page 17: ...ts closest to front of fixture 2nd 420 460 Lamp in second sockets from front of fixture 3rd 10 000 K Lamp in third sockets from front of fixture 4th 420 460 Lamp in sockets closest to back of fixture...

Page 18: ...t over a metal Anchor and insert the included screw through the Mount and into the Anchor Tighten the screw until the Anchor pulls against the inside of the channel and secures the Mount to the fixtur...

Page 19: ...into a grounded outlet GFCI The display will illuminate when power is supplied The Digital Timer controls three Zones in the Marine Light Fixture 10 000 K Lamps 420 460 Lamps and Lunar LED s Each of t...

Page 20: ...ced every 9 to 18 months It is best to review the requirements for your animals prior to replacing the Lamps Consult your local store or supplier for a recommendation for frequency of replacement To r...

Page 21: ...me of operation Pre Programmed Times of Operation For ease of use the individual Lamp types are pre programmed with START and END times If the timer is in the Pre programmed mode the display will show...

Page 22: ...ctrical current is leak ing from the circuit If a leak is determined the GFCI will switch the power off LED Light Emitting Diode A diode is the simplest sort of semiconductor device The semiconduc tor...

Page 23: ...ying the product THIS CONSTITUTES AQUATIC LIFE S ENTIRE WARRANTY AND AQUATIC LIFE MAKES NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCT AQUATIC LIFE LLC SPECIFICALLY DISCLAI...

Page 24: ...Aquatic Life Live it Today and Life Rewards are trademarks of Aquatic Life LLC Los Angeles CA 90058 www aquaticlife com Copyright Aquatic Life LLC P N 9000061 07 2009...

Reviews: