![Aquatica Digital 20086 Series Manual Download Page 24](http://html1.mh-extra.com/html/aquatica-digital/20086-series/20086-series_manual_2961822024.webp)
24 |
Flash triggering
Bringing back housing to ambient pressure:
Once your housing is under vacuum, it is important to bring it back to ambient
pressure before attempting to remove the port or to open the housing. To
pressurize your housing, insert the pump back into the valve (STEP 4) and
remove pressure release plug (#6). Once the hissing sound stops, you can
remove the pump (STEP 7). The housing is now at ambient pressure.
Flash triggering
There are three flash options compatible with the AZ6/7 housing
Optical triggering ( #20086-OPT-VC)
Nikonos
-style bulkhead (#20086-NK-VC)
Ikelite
-style bulkhead (#20086-KT-VC)
For
Nikonos
and
Ikelite
style bulkheads, simply insert the velcroed board
inside your camera hot-shoe then connect
your strobe’s cables following the
manufacturer
’s
instructions.
Note:
If your housing fails to maintain a constant vacuum, proceed a
thorough inspection of the user serviceable O-rings of the housing. If
unsuccessful in determining the source of the leak, refrain from
immersing the housing and return it to your authorized service
center for inspection.
Note:
Note that none of the offered flash triggering options are TTL compatible.