RAPID/X6

PLUMBER’S CONDENSED

INSTALLATION GUIDE

SUPPLIED CONTENTS

RAPID/X6

OWNER’S
MANUAL

RAPID UNIT

1. LOCATION SELECTION

CONDENSATE 
DRAINAGE
ELBOW (connected)

2. BASE

PTR

• This unit is designed for external operation only and requires a continuous supply of air to operate efficiently.
• Avoid installation in areas where falling debris, such as leaves, is prevalent as this may result in air vents being 
blocked or the unit being damaged.
• Avoid placing the system in locations with multiple walls or structures.
• Always maintain optimum perimeter from all structures.

• The unit should be installed on a concrete plinth or stable structure capable of sustaining weights in excess of 
315kg. 
• A minimum dimension of 600mm x 600mm is required. Please ensure that all four  feet are supported by the 
base being used otherwise warranties may be voided.
• Unit is to be installed level to ensure condensation drainage is not impaired.

pg.1

Top profile

600mm

fan exhaust

150mm

Structure

Side profile

600mm

150mm

300mm