RAPID/X6
PLUMBER’S CONDENSED
INSTALLATION GUIDE
SUPPLIED CONTENTS
RAPID/X6
OWNER’S
MANUAL
RAPID UNIT
1. LOCATION SELECTION
CONDENSATE
DRAINAGE
ELBOW (connected)
2. BASE
PTR
• This unit is designed for external operation only and requires a continuous supply of air to operate efficiently.
• Avoid installation in areas where falling debris, such as leaves, is prevalent as this may result in air vents being
blocked or the unit being damaged.
• Avoid placing the system in locations with multiple walls or structures.
• Always maintain optimum perimeter from all structures.
• The unit should be installed on a concrete plinth or stable structure capable of sustaining weights in excess of
315kg.
• A minimum dimension of 600mm x 600mm is required. Please ensure that all four feet are supported by the
base being used otherwise warranties may be voided.
• Unit is to be installed level to ensure condensation drainage is not impaired.
pg.1
Top profile
600mm
fan exhaust
150mm
Structure
Side profile
600mm
150mm
300mm