background image

User's Manual and Installation Guide 

Aquajet RV Series

Aquajet ES Series

Please read the following instructions before attempting an installation.  When properly installed,
both the Aquajet RV and ES  Series can be used in virtually any existing RV.
If you prefer to have the pump professionally installed, contact Aquatec (949-225-2200) to locate
your nearest authorized service center.

WARNING

The 5-chamber Aquajet RV and ES Series are more powerful than most existing RV water pumps
and, as a result, may draw more current (Amps) than the pump(s) they replace.  It is imperative that
any power supply, fuses/circuitbreakers, wiring, switches, connectors, or controllers that are used to
supply 12 VDC to the pump are adequately sized.  Inadequately sized components may overheat,
causing an electrical fire. 

When installing either an Aquajet RV or ES Series pump, 

positive voltage (+12VDC) must be con-

nected to the Aquajet's red fused leadwire.

Reversing polarity will instantly blow the fuse and

may permanently damage the controller.

If you are uncertain with respect to any of this information, Aquatec highly recommends that a quali-
fied technician perform your installation and determine the existing polarity of your current wiring.

Safety Tips:

1.  Never operate the pump in an atmosphere where flammable gases may be present, since arcing

at the motor brushes or switch contacts may cause an explosion.

2.  After extended operation, or if malfunctioning, metal surfaces of the pump may become hot and

cause burns if touched. If this occurs, disconnect electrical power and wait 30 minutes before
touching pump.

3.  Never mount the pump where the surface temperature of the motor or the controller (200 F maxi-

mum) may cause ignition of the surrounding materials.

IMI-114, REV C

Summary of Contents for Aquajet ES Series

Page 1: ...electrical fire When installing either an Aquajet RV or ES Series pump positive voltage 12VDC must be con nected to the Aquajet s red fused leadwire Reversing polarity will instantly blow the fuse an...

Page 2: ...holding tank and the pump to prevent debris from entering the pump Particulate matter may cause the valves inside the pump to stick open This filter needs to be cleaned on a regular basis or it will r...

Page 3: ...he existing wiring including the colors of the wires and how they are attached If you do have an Intellitec controller that does not say either 10 Amp or 15 Amp on the label then you must either a Rep...

Page 4: ...ey the existing plumbing and identify the suction line i e the line going from the water hold ing tank to the pump If there is not a screen filter currently on this line then one should be pro cured f...

Page 5: ...ide for additional infor mation b Check your RV Owner s Manual for the recommended fuse rating for the pump branch cir cuit If your recommended rating is rated 10 Amps or more you can proceed directly...

Page 6: ...ard Polybutylene or PEX tubing If your RV is currently plumbed with soft walled reinforced hose see Diagram 5 then your system should be perfectly sufficient as is By installing a piece of IAPMO appro...

Page 7: ...d end of Qest threaded adapter into outlet port marked with arrow pointing away from pump of the Aquajet pump Lock fitting in place by pushing down retainer slide 7b For old pump outlets directly conn...

Page 8: ...ttery 19 Have an assistant briefly power up the pump using one of the RV s standard pump switches 20 Water should be flowing into bucket see Figures 6 and 7 or into the sinks see Figure 5 21 Allow Aqu...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...ermore this warranty does not cover any damage or defects occurring from customer s fail ure to follow pump label instructions or Operational and Installation Guidelines The warranty guarantees that p...

Reviews: