background image

9

AQUASURE 

PREMIER SERIES

Summary of Contents for AS-PR100E

Page 1: ...PREMIER SERIES DRINKING WATER SYSTEM OWNER S MANUAL FOR MODEL NO AS PR50S AS PR75A AS PR100P ...

Page 2: ......

Page 3: ...Saddle Installation STEP 3 Tank Ball Valve Installation STEP 4 Drinking Water Faucet Installation STEP 5 Mounting or Placement of the System STEP 6 Connecting the System STEP 7 System Startup SYSTEM MAINTENANCE Filter Replacement Time Frame Removing the FLOWLOK Tray Replacing Stage 1 2 Pre Filters Replacing Stage 3 4 RO membrane and Post Carbon Filter SYSTEM TROUBLESHOOTING LIMITED PRODUCT WARRANT...

Page 4: ...enches or adjustable Philips screwdriver Flashlight or Drop Light Protective eye wear i e goggles System Components Breakdown See Dia A Thank you for choosing Aquasure Before you start using your Aquasure drinking water system take a few minutes to become familiar with the basics Filter replacement Be sure to change your Aquasure water filters according to the recommended filter replacement schedu...

Page 5: ...3 AQUASURE PREMIER SERIES Instruction continues on the next page Dia A 1 2 3 4 5 6 7 9 10 8 13 17 16 11 14 12 15 18 ...

Page 6: ...e is confirmed to be lower than 75 psi A pressure regulator must be installed on the feed water source coming into the home to reduce water pressure going into the system and ensuring water pressure does not exceeds 75 psi 3 Water Condition Parameters Turbidity 5 NTU pH 4 11 Hardness 7 grains per gallon 120 ppm Sulfide Iron Manganese 0 01 ppm Chlorine 2 ppm Total Dissolved Solids TDS 1 000 ppm WAR...

Page 7: ... break due to the added weight of the water System Dimensions 15 w x 5 25 d x 15 h System Weight 8 lbs 3 6kg Tank Dimensions with Valve 11 3 d x 16 75 h Tank Capacity 1 9 3 2 gal 7 2 12 1L Tank Weight 6 6 lbs Empty 40 lbs Full Varies by water pressure III Feed Water Adapter with 3 8 and 1 2 Connection Setup Note The feed water adapter is setup to work with either 3 8 or 1 2 cold water line Please ...

Page 8: ... connection is made it is advisable to cut off 1 4 from the end of the tubing using these fittings 1 Quick Connect Tubing Installation Inspect Tubing See Diagram C 1 The system comes with pre cut tubing that is cut cleanly and squarely to ensure proper connection Please ensure that the tube has a smooth outside diameter without any burrs chamfers or score marks prior to inserting it into the fitti...

Page 9: ... outlet under the main faucet If the spray hose uses a diverter at the base of the spout be sure to remove it to avoid trouble later on Hanging faucet If drilling a hole is not feasible i e rental home drill tool not available etc the faucet can be placed inside the sink cabinet or wherever convenient without mounting 2 Pre drilling preparation Check under the sink in the area that you plan to ins...

Page 10: ...rill area as drilling at high speed will create a lot of heat which can cause the metal to warp or burn Using the 6mm drill bit at half speed to drill the hole This would help prevent it from overheating Switch to 7 16 11 mm drill bit and do the same to widen the hole Once the hole is drilled use the file to smooth out the edges and wipe away the shaving Clean The Area Discard paper towels and new...

Page 11: ...9 AQUASURE PREMIER SERIES ...

Page 12: ... to see if the cold water line is completely shut off by turning on the faucet in the cold water position If cold water cannot be turned off the main water supply to the house must be shut off for the installation Connecting with Flex Line Riser See Diagram D 1 1 Loosen the nut and separate cold water riser tube from faucet shank Gently bent riser tube so that the feed water adapter fits onto the ...

Page 13: ...it stops Note If the hole in the copper tube is not adequately pierced this may prevent sufficient cold water supply to flow to the system and reduce the system performance In this event open and close the self piercing valve several times to ensure an adequate pierced tube Test For Leaks 1 Make sure the feed water adapter is in the shut off position perpendicular to the feed connection See Diagra...

Page 14: ...gram E 3 CAUTION Do not over tighten Over tightening may cause the drain saddle to break or crush the drain pipe STEP 2 Drain Saddle Installation 1 Locate the optimal placement on the drain pipe to install the drain saddle See Diagram E 1 Note The drain saddle should be installed above the trap and on the vertical or horizontal tail piece To reduce potential drainage noise it is ideal to mount the...

Page 15: ...th an adjustable wrench Tighten the chrome nut until the faucet assembly does not move A faucet wrench is recommended if the space for proper mounting is very limited CAUTION Do Not over tighten the adapter to avoid breaking and leak 5 Attached the faucet adapter to the shank 1 Attached the tank ball valve on top of the tank CAUTION Do Not over tighten the adapter to avoid breaking and leak Dia F ...

Page 16: ...he cabinet floor to the base of the system See Diagram H 1 IMPORTANT Be careful not to kink any of tubing on the system as kinked tubing can rupture and leak 2 Using a pencil or marker and mark the mounting hole on the back of the bracket onto the wall Note Please make sure the bracket mount is leveled using a level tool to ensure evenly distributed stress on the bracket 3 Set the system aside 4 S...

Page 17: ...bing from the SHOKBLOK protection valve A to feed water adapter B 2 Connect the BLACK color coded tubing from drain water connection C to Drain saddle D 3 Connect the BLUE color coded tubing from system E to Pressurized Water Storage Tank F 4 Connect the BLUE color coded tubing from the system post filter G to faucet adapter H Note if you purchase the optional extra output kit please follow to sup...

Page 18: ...2 to 3 hours for the water storage tank to fill The system will automatically shut off once the tank is full 5 Check for leaks The system is now filled with water and pressurized 6 Drain out the first tank of water by turning on the dispensing faucet Have the water run till it becomes a slow stream of water or when it starts to trickle See Diagram J 4 STEP 7 System Startup WARNING Immediately shut...

Page 19: ...e http www aquasureusa com warranty registration to begin the online registration process Mount the system onto the wall or placed in a secure location Turn off the FLOWLOK lever and insert the compressed safety disc inside the holder and turn the lever back on See Diagram J 5 Turn off the drinking water faucet to let the water storage tank replenish the product water Check one last time on all th...

Page 20: ...2 years Private well water source may need to replace membrane sooner than 2 year due to lower source water quality Post Stage Taste Refining Filter Recommend replacing with the RO Membrane I Removing the FLOWLOK Tray CAUTION If the system is equipped with FLOWLOK leak detector The tray must be removed before replacing the filters Failure to do so may cause the safety disc to expand and trip the a...

Page 21: ... to the system See Diagram L 2 3 Turn on drinking water faucet lever briefly to release the water and relief the built up pressure inside the system This will make removing of filters easier See Diagram L 3 5 Replace the system with new Pre Stage Filters by setting them on to the system and twisting them quarter turn to the left See Diagram L 5 6 Repeat the same process for stage 2 7 Turn ON cold ...

Page 22: ...he RO Membrane and Post Stage Taste Refining Filter quarter turn to the right to unseat the filters from the system 6 Replace the system with new RO Membrane and Post Stage Taste Refining Filter by twisting the filters quarter turn to the left 7 Make sure the RO Membrane and Post Stage Taste Refining Filter are firmly locked in with the system 8 Re attached the black tubing with the flow restricto...

Page 23: ...21 AQUASURE PREMIER SERIES ...

Page 24: ...ded level D Reverse osmosis membrane is fouled Make sure incoming water pressure is within operating limits Make sure drain line is not clogged and replace the membrane E Air pressure in holding tank is incorrect Empty water from holding tank Air pressure in valve stem should be between 5 10 psi F Air bladder in holding tank is ruptured Replace the holding tank G Holding tank valve is closed Open ...

Page 25: ...p B Drain line is clogged Clear Tubing C Drain flow rate is too high Replace flow restrictor 4 Drain water overflows at the air gap faucet CAUSE CORRECTION A Clogged pre filters Replace Filter B Low Incoming water pressure Incoming water pressure must be above 40 psi Install a booster pump or permeate pump C Reverse osmosis membrane is expanded If membrane life is unusually short check the TDS lev...

Page 26: ...icient water pressure Incoming water pressure must be above 40 psi Install a booster pump or permeate pump H Incorrect installation Check the installation guide and make sure all the steps are installed properly 7 Little to no water at dispensing faucet CAUSE CORRECTION A Air bubble trapped inside the housing Purge the air by tilting the system on one side shut off the tank ball valve and turn on ...

Page 27: ... automatic shut off valve is defective and needs to be replaced B Automatic shut off valve is not defective and incoming water pressure is too low Incoming water pressure must be above 40 psi Install a booster pump or permeate pump C System is feeding multiple outlets or an outlet that demands water constantly It is normal in this situation as system needs to constantly produce water to supply the...

Page 28: ...e repair or replacement and shall be limited to the repair or replacement of only the specific Product that fails due to a manufacturing defect Any repaired or replaced product shall also remain subject to the original one 1 year warranty from the date of the original purchase and any repair or replacement shall not extend the original warranty period in any manner or start a new warranty period C...

Page 29: ...oever as to the result of the use of the product purchased whether used singularly or in combination with any other products or substances No claim by the buyer owner of any kind including claims for indemnification shall be greater in amount than the purchase price of the products in respect to which damages are claimed In no event shall Aquasure be liable to buyer owner in tort contract or other...

Page 30: ......

Page 31: ......

Page 32: ...www AquasureUSA com 818 N Mountain Ave 203c Upland CA 91786 800 661 0680 sales aquasureusa com ...