www.aquasafecanada.com   |   Maximus II Installation Instructions 05/13   |   page 1

1.0  Relax, take your time.  You will find this process easy and straight forward.

municipal or

well water

(feed water)

Aqua-safe

exclusive E-Z Flush

Flow Restrictor

waste water drain

5, 6 & 7th Stages

De-Ionization (DI) 

Cartridge for 

super clean water

www.aquasafecanada.com

4 way Auto 

Shut-off 

Valve (ASV)

yellow tubing

red tubing

blue

tubing

white

tubing

red

tubing

manual

shut-off

valve

Pure water outlet 

to aquarium

4th Stage

Membrane 

Housing

1st Stage: 5 Micron Sediment
2nd Stage: 5 Micron Granular Activated 

Carbon for chemicals
3rd Stage: 1 Micron Coconut Carbon Block for chemicals

Aquarium Dual System - Front View

Pure water outlet 

to faucet, icemaker etc.

8th Stage 

Final Polishing Filter

for taste

Reservoir Tank

Float Valve

automatically

tops up

Sump Tank

SUMP TANK

Manual

Shut Off

Valve

3

Pre

Filters

waste water drain

4th Stage

Membrane 

Housing

Aqua-safe

exclusive E-Z Flush

Flow Restrictor

5 & 6th Stages

De-Ionization (DI) 

Cartridge for 

super clean water

Back View

of membrane housing

Simply follow the step by step instructions below. Please 
do not make the mistake of skipping a step.

FOR REFERENCE PURPOSE ONLY: Directly below is a 
schematic showing the positioning of all tubing in a fully 
set up system. Please read the instructions step by step. 
The install is straight forward but reading through each 
step is crucial to completing your install properly in the 
least amount of time possible.

The installation should take 60 - 90 minutes and when all 
is set up you will have ultra pure water for the health and 
enjoyment of your family & aquatic pets. 
Did you know? Reverse Osmosis literally is the most 
powerful water filtration method known to man. 

¬

Congratulations, you have just taken a huge step 

towards better overall health of your family and your 
aquatic pets and a bonus of cost savings and conve-
nience to you by producing your RO/DI water at home.

Contents

Installation Instructions for Aquarium II Dual Reverse Osmosis System & COMBO

1.0  Relax, take your time.  You will find this process easy and straight forward.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.0  Take everything out of the box   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.0  Remove the protective plastic from the prefilters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
4.0  Inserting the R.O. Membrane  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

4.1  Inserting the pre-filter elbow adaptors  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

5.0  Preparing the Feed Water to your system   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

5.1  Special note about braided wire plumbing  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.2  Installing the Needle Piecing Saddle Clamp to the cold water line.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.3  Connecting the feed water line to your system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.4  Piercing the cold water line  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5.5  Flushing of the Pre-filters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

6.0  R.O. Membrane feed water line hook-up (pre-filter to R.O. Membrane)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
7.0  Setting the Flow Restriction Ratios of your System.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
8.0  Installing the first D.I. Resin Canister   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9.0  Installing the second and third D.I. Resin Canisters   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10.0  Installing the Final Polishing Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
11.0  Prepare the R.O. Water Holding Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
12.0  Clear the Decks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
13.0  Preparing the Discharge Water Saddle Clamp.   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
14.0  Installing the Faucet.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
15.0 Connecting auto top-up Float Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Extra information for the Aquarium II Dual COMBO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Where do I install the PSI Meter from my “COMBO” System? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
How do I use the TDS Meter from my “COMBO” System?  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
How do I store my 24oz bag of extra D.I Resin Beads?  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
How do I store my extra case of 21 (6 changes) pre-filters and post-filters?   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17

Leak Prevention Page  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Threaded Fittings   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Pre-Filter Canister Housing   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
DI Resin Canister  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Aquarium II Dual System Filter Change Schedule   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Stage 1,2 & 3 Pre-Filters – When to conduct a filter change.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Stage 4 – When should I change the Reverse Osmosis Membrane? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

Testing to see if your R.O. Membrane needs replacing.  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Are you unsure when you last replaced your R.O. Membrane? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Stage 5, 6 & 7 –  When should I change the resin in the D.I. Resin Canisters?  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Stage 8 –  When should I change the Final Polishing Filter?  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Aquarium II Dual System Filter Change Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Pre-Filters – How to conduct a filter change.   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
R.O. Membrane  – How to change the R.O. Membrane of your system.   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
D.I. Resin Canisters - How to change the D.I. Resin Beads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Final Polishing Filter - How to change the Final Polishing Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Water Systems & Parts Warranty Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Summary of Contents for Aquarium II Dual R.O./D.I. System

Page 1: ...commend a fully automatic booster pump which is found on our websites general parts and accessories page We also highly recommend a booster pump if your water is extremely turbid with ppm counts beyond 600ppm The installation instructions that follow are extremely detailed if a leak is experienced during installation please see the Leak Prevention Section on page 18 ATTENTION It is extremely impor...

Page 2: ...l Reverse Osmosis System COMBO 1 0 Relax take your time You will find this process easy and straight forward 1 2 0 Take everything out of the box 2 3 0 Remove the protective plastic from the prefilters 2 4 0 Inserting the R O Membrane 3 4 1 Inserting the pre filter elbow adaptors 3 5 0 Preparing the Feed Water to your system 3 5 1 Special note about braided wire plumbing 4 5 2 Installing the Needl...

Page 3: ...s water inlet side water outlet side Figure 5 Screw elbow adaptors into inlet and outlet of the pre filter housings www aquasafecanada com Insert blue RO Membrane into housing Screw cap on housing 1 2 Membrane housing blue RO Membrane Cap Figure 4 Inserting the R O Membrane in to its housing TIP 2 0 Take everything out of the box Examine the contents of the Large and Small Parts Bag against the di...

Page 4: ...view 5 1 Special note about braided wire plumbing Please Note DO NOT ATTEMPT TO INSTALL THE NEEDLE PIERCING SADDLE CLAMP TO BRAIDED WIRE PLUMBING Fig 6 You can install the needle piercing saddle clamp to all other forms of cold water lines found under the common sink just not the kind of plumbing de picted in Fig 6 The braided plumbing in Fig 6 is too soft a material and will therefore not allow f...

Page 5: ... for clarity 1 2 Put a bowl or bucket under the short piece of blue tubing coming out of the ASV to catch the PERMEATE water cleaned by the R O Membrane E Z Flush Flow Restrictor Close the E Z Flush Flow Restrictor and turn the Manual Shut Off Valve on blue tubing Manual Shut Off Valve to water supply 3 Figure 12 Preparing to set up the E Z Flush Flow Restrictor You can now turn your home s emerge...

Page 6: ...n do ing this timed measurement the permeate water should take three times as long to fill the same volume over that of the brine water 3 1 Ratio We do not recommend anything over a 1 1 ratio as it is extremely important for the R O Membrane to have adequate BRINE flow to be able to flush away the harmful particulates it is removing while filtering the water A setting near to or at 1 1 ratio is on...

Page 7: ... I Canister and connect it to the second D I Canister using a 4 inch length of blue tube 3 Connect the last elbow to the right side of the third D I Canister www aquasafecanada com D I Canisters rotated back to make room elbow elbow www aquasafecanada com The Final Polishing Filter remineralizes your water to ensure it has a full bod ied taste Because of this the ppm of the water dispensed at your...

Page 8: ...mply press the saddle clamp firmly onto the drain in order to catch the bolts on the opposite side TIP Figure 23 Assembling and attaching the drain saddle clamp rubber gasket quick connect fitting drain pipe yellow drain line Insert yellow drain line into quick connect fitting rubber gasket 1 2 Remove the backing from the gasket and stick it to the inside of the saddle clamp making sure that the y...

Page 9: ...ver use it again you would probably be better off either renting the equipment or calling in a Pro Most glass installers have diamond drills and all vendors of stone have them Some will rent it out as will Rent All stores Start the hole by drilling a hole in a piece of scrap wood This will serve as a guide Hold the piece of wood and let the diamond drill bit do the work DO NOT push down or apply p...

Page 10: ...all the PSI Meter onto your system there one area where installing the PSI Meter on your system can be of use Option 1 If you are on a well water system and you think you may have lower then 50 psi through out your home s plumbing a good place to install the PSI Meter is on the feed water line to your Reverse Osmosis System between the Manual Shut Off Valve and the inlet to the first pre filter ho...

Page 11: ...II Dual System Filter Change Schedule Pre Post filters Defined as the filter stages Pre before RO Membrane and Post after RO Membrane Stage 1 2 3 Pre Filters When to conduct a filter change Stages 1 2 and 3 are your system s pre filters which need to be changed every 1000 gallons of purified water produced The average household consumes 3 5 gallons of drinking and cooking water daily At 5 gallons ...

Page 12: ...er back ON with the Manual Shut Off Valve NOTE Back View hanging bracket not shown for clarity Manual Shut Off Valve in OFF position E Z Flush Flow Restrictor feed water in yellow tubing to discharge saddle clamp 3 TDS Meter Figure 29 How to depressurize your system Figure 30 Testing your permeate water with the TDS meter WARNING Are you unsure when you last replaced your R O Membrane Because the ...

Page 13: ...re filters for 10 15 minutes 4 5 feed water in yellow tubing to discharge saddle clamp DONE After the 10 15 minute flush turn Manual Shut Off Valve back OFF and reconnect the white and yellow tubes to their original positions If this is the only filter change you are doing at this time you can turn the Manual Shut Off Valve and Tank Top Valve back ON and you are to faucet 3 Way T www aquasafecanad...

Page 14: ...y pushing the canister down onto its canister clips Repeat for second and third D I Canisters Reinsert the blue tubing into the elbows on both sides of the D I Resin Canister Turn on the Manual Shut Off Valve and Tank Top Valve to repressurize your system Figure 36a Replacing the D I Resin Beads If you are done replacing filters for now you can re pressurize your system by turning on the feed wate...

Page 15: ...ceeds 113 F 45 C The membrane is not subjected to a pH lower then 4 or higher then 11 The membrane is exposed to water pressure greater then 150 psi The membrane is allowed to dry out after its initial wetting The Membrane should always be kept moist after its initial exposure to water If the membrane is exposed to greater than 1500 PPM water BOOSTER PUMPS Reverse Osmosis Booster Pumps are warrant...