AQUAPHOR DWM-203 Performance Manual Download Page 6

6

 

 

 

The installation of junction point* (fig. 4)

 

 

Turn  the  water  off  at  the  mainline  on  the  highway  of  cold 

water-supply.

 

 

Open  the  kitchen  mixer  tap  in  order  to  depressurize  water 
pipe. 

 

 

Unscrew cap nut of flexible connection at the mainline on the 
highway of cold water-supply, stand for mixer tap.

 

ATTENTION!  In  the  flexible  tube,  after  a  pressure 
release, a small amount of water may remain. When 
disconnecting the flexible connector, use a capacity 
of  about  200  ml  to  drain  the  remaining  water  in  the 
tube.

 

 

Screw  the  cap  nut  of  the  junction  point  to  the  threads  of 
mainline on the highway of cold water-supply.

 

ATTENTION! Ensure that the seal pad is in place and 
is not damaged when mounting the product.

 

 

Screw  the  cap  nut  of  flexible  connection  on  the  threads  of 

junction point.

 

 

Close the inlet tap of the connection unit and, having supplied 
water  from  the  cold  water  supply  line,  make  sure  that  the 

connection is hermetically sealed.

 

 

Joint the tube JG.

 

 
 
 
 

 

Inlet tap set to position 

«Closed»

 

Key lock clip

 

 
 
 
 
 
 

 

Junct

ion point

 

Seal pad 

 

 

 

Cold water-

 

supply

 

 

Fig. 4

 

 
 

 

 

 

 

Fig. 5а

 

 

 

 

 

 

Fig. 5b

 

 
 

 

 

* * The manufacturer reserves the right to use the connection points and cranes of a similar design. If you have any questions, please contact the service provider.

 

How to connect the pipes JG (fig. 5a) 

Pull 

out the key lock clip from under the plastic 
sleeve, insert the pre-tipped end of the tube into 
the choke bean to the depth of about 15 mm to 
the stop and emplace the clip.

 

How to disconnect the pipes JG (fig. 5b) 

Pull the locking clip out from under the plastic 
sleeve and, pressing the end of the plastic 
sleeve, pull out the tube.

 

Check the strength of the tube. At 
an effort of 8-10 kgf the tube 
should not be pulled out.

 

Summary of Contents for DWM-203

Page 1: ...AQUAPHOR Water filter DWM 203 Performance manual Aquaphor LLC Russian Federation...

Page 2: ...ineralized the greater the tap water pressure is required for the performance DWM 203 Materials DWM 203 are safe non toxic and do not release into the water hazardous substances for human health and t...

Page 3: ...kage 5 Drainage collar 8 1 package 6 Utility collar 9 2 pc 7 Key 10 1 pc 8 Tap for clean water 11 1 package 9 Performance manual 1 pc 10 Installation instruction 1 pc Voltage input 100 240 V AC Input...

Page 4: ...clean water at any time in the required quantities the DWM 203 is equipped with a storage tank for clean water On the front the DWM 203 is covered with a decorative panel in which there is an electro...

Page 5: ...for clean water and DWM 203 In this case pay attention to the fact that the supply tubes pass freely without fractures and bends fig 3 DWM 203 must be removed or insulated from heat sources cookers bo...

Page 6: ...on the threads of junction point Close the inlet tap of the connection unit and having supplied water from the cold water supply line make sure that the connection is hermetically sealed Joint the tu...

Page 7: ...ng for the tube Drill a hole 7 mm in diameter in the wall of the pipe in the marked location Remove the cut part in the form of a circle from the pad 1 Fig 6 Remove the protective film 2 from the pad...

Page 8: ...module insert it into the appropriate collector until it stops and turn to the right along the arrow as shown in fig 10a until it clicks To detach the module push the stop button all the way to the st...

Page 9: ...ity plugs from the seats of the reverse osmosis membrane unit and install the membrane modules in their place as shown in fig 14 Switch in the input tap of the junction point to the position Opened LE...

Page 10: ...the filter units indicates the unworked resource of the modules LED indicator 5 see figure 15 will flash in the event of a malfunction at the rest of the time it is lit continuously which indicates t...

Page 11: ...ress and hold the PUSH button for at least 7 seconds to reset the module resource The light indication of the pre treatment unit will change from a flashing mode to a constantly flashing mode and the...

Page 12: ...ot use the system to purify water of unknown quality that has not undergone additional disinfection Purified water is not subject to long term storage We recommend to use fresh filtered water Utilizat...

Page 13: ...time resource of replaceable filtering modules Name Service lifetime resource Preliminary water treatment unit Module 5 3 4 months 1 Module 2 3 4 months 1 Block of reverse osmosis membranes Replaceabl...

Page 14: ...be replaced Plug of power unit is not inserted into the socket Do insert plug of power unit into the socket The power supply plug is not inserted into the DWM 203 coaxial connector Insert the power su...

Page 15: ...DWM maintenance service Date Foreman Work type Note...

Page 16: ...nking Water without reflecting them in the passport Drinking water machine Aquaphor DWM 106 31C trade name Automata drinking water machine Aquaphor DWM 203 TS 3697 049 11139511 2014 Certificate of con...

Reviews: