  4. Design and function of DWM-203 

 

 
 
 
 
 
 
 

 

1

 

 

 

2

 

 

3

 

 

4

 

 
 

Fig. 2

 

 

Basic units DWM-203 (fig. 2): 1 – 
Body assembly DWM-203;

 

2

 

– Replaceable module К5 of preliminary water 

treatment unit;

 

 

3

 

– Replaceable module К2 of preliminary water 

treatment unit;

 

4

 

– Reverse-osmotic membrane unit (2 pc).

 

1.  Body  DWM-203  (1) 

consists  of  tabletop,  cover,  stand,  storage  container  and  front  panel.  Four  collectors  (for 

joining of  replaceable  filtering  modules) are  fixed  in  top  plate,  hydroautomatics  block.  Top plate  is  capped with  cosmetic 

cover,  in  the  central  part  of  which  there  is  a  handle  that  fixes  the  cap.  In  lower  main  body,  stand,  there  is  a  pump  for 

increasing the water pressure in the DWM-203. In order that you can use clean water at any time in the required quantities, 

the DWM-203 is equipped with a storage tank for clean water. On the front, the DWM-203 is covered with a decorative panel, 

in which there is an electronics unit with control elements.

 

2. The composition of the preliminary water treatment unit (2, 3) 

includes replaceable filter modules 

K5 and K2.

 

The pre-treatment unit is designed to remove impurities from the water that can damage the reverse-osmotic membrane, 

such as iron hydroxide and active chlorine.

 

3.  The  reverse  osmosis  membrane  (4) 

includes  two  replaceable  membrane  modules.  Back-osmotic 

membranes block purifies water from organic and inorganic compounds, salts, and softens water.

 

 

 

 

ATTENTION! The performance of the DWM-203 depends on the pressure

 

In the water pipe. The proper operation of DWM-203 at a pressure in the 
water pipe below 0.14 MPa (1.4 at) is not guaranteed.

 

Summary of Contents for DWM-203

Page 1: ...AQUAPHOR Water filter DWM 203 Performance manual Aquaphor LLC Russian Federation...

Page 2: ...ineralized the greater the tap water pressure is required for the performance DWM 203 Materials DWM 203 are safe non toxic and do not release into the water hazardous substances for human health and t...

Page 3: ...kage 5 Drainage collar 8 1 package 6 Utility collar 9 2 pc 7 Key 10 1 pc 8 Tap for clean water 11 1 package 9 Performance manual 1 pc 10 Installation instruction 1 pc Voltage input 100 240 V AC Input...

Page 4: ...clean water at any time in the required quantities the DWM 203 is equipped with a storage tank for clean water On the front the DWM 203 is covered with a decorative panel in which there is an electro...

Page 5: ...for clean water and DWM 203 In this case pay attention to the fact that the supply tubes pass freely without fractures and bends fig 3 DWM 203 must be removed or insulated from heat sources cookers bo...

Page 6: ...on the threads of junction point Close the inlet tap of the connection unit and having supplied water from the cold water supply line make sure that the connection is hermetically sealed Joint the tu...

Page 7: ...ng for the tube Drill a hole 7 mm in diameter in the wall of the pipe in the marked location Remove the cut part in the form of a circle from the pad 1 Fig 6 Remove the protective film 2 from the pad...

Page 8: ...module insert it into the appropriate collector until it stops and turn to the right along the arrow as shown in fig 10a until it clicks To detach the module push the stop button all the way to the st...

Page 9: ...ity plugs from the seats of the reverse osmosis membrane unit and install the membrane modules in their place as shown in fig 14 Switch in the input tap of the junction point to the position Opened LE...

Page 10: ...the filter units indicates the unworked resource of the modules LED indicator 5 see figure 15 will flash in the event of a malfunction at the rest of the time it is lit continuously which indicates t...

Page 11: ...ress and hold the PUSH button for at least 7 seconds to reset the module resource The light indication of the pre treatment unit will change from a flashing mode to a constantly flashing mode and the...

Page 12: ...ot use the system to purify water of unknown quality that has not undergone additional disinfection Purified water is not subject to long term storage We recommend to use fresh filtered water Utilizat...

Page 13: ...time resource of replaceable filtering modules Name Service lifetime resource Preliminary water treatment unit Module 5 3 4 months 1 Module 2 3 4 months 1 Block of reverse osmosis membranes Replaceabl...

Page 14: ...be replaced Plug of power unit is not inserted into the socket Do insert plug of power unit into the socket The power supply plug is not inserted into the DWM 203 coaxial connector Insert the power su...

Page 15: ...DWM maintenance service Date Foreman Work type Note...

Page 16: ...nking Water without reflecting them in the passport Drinking water machine Aquaphor DWM 106 31C trade name Automata drinking water machine Aquaphor DWM 203 TS 3697 049 11139511 2014 Certificate of con...